- Advanced Polymer Chromatography (APC)
- UPLC with UV Detection
- GC
- GC-MS
- HPLC with RI, ELSD, Electrochemical, Fluorescence or Conductivity Detection
- HPLC or Prep Systems with UV Detection
- SFC and Convergence Chromatography (UPC2)
- Single Quadrupole Mass Detection
- Tandem Quadrupole (Triple Quadrupole )
- Time-of-flight Mass Spectrometry
- Amino Acids
- Cations
- Gel Filtration
- Gel Permeation
- Glycans
- Ion Calibration
- Oligonucleotides
- Peptides
- Pesticides
- Proteins
- QC Trace Metals
- Small Molecules
- Total Chlorine
- pH Buffers
- Quality Control (QC) Reference Material
- Reagents
- System Performance Standards and Reagents
Find Your Results


The protein consumable line originates from an internal need to have relevant application standards for benchmarking system performance. Many of these standards can also be found on corresponding Waters columns Certificate of Analysis’ since they are also used for QC validation of columns. These specifically formulated standards are prepackaged in Waters vials which allows for direct solubilization providing ease of use, minimizing sample loss and discrepancies. To have reliable and dependable standards is important and saves valuable research and development time.
BEH125 Protein Standard Mix [186006519]
The BEH125 SEC Protein Standard Mix is used to benchmark the ACQUITY UPLC Protein BEH SEC 125, 1.7 µm Columns. This standard should be used on a regular basis for evaluation of column and system performance.

BEH200 SEC Protein Standard Mix [186006518]
The BEH200 SEC Protein Standard Mix is used for benchmarking the ACQUITY UPLC Protein BEH SEC 200, 1.7 µm Columns. This standard should be used on a regular basis for evaluation of column and system performance.

BEH450 SEC Protein Standard Mix [186006842]
The BEH450 SEC Protein Standard Mix is used to benchmark the ACQUITY UPLC Protein BEH SEC 450, 2.5 µm Columns.It is recommended that this standard be used on a regular basis for evaluation of column and system performance.

Biopharmaceutical Preparation Kit [186007517]
Biopharmaceutical Preparation Kit is a component of the Biopharmaceutical Training Kit used in conjunction with Biopharmaceutical Training Standards Kit which was designed to provide trainers and customers with high quality standards that can be utilized as a starting point for running biopharm applications on Waters ACQUITY UPLC inlet with Q-Tof mass spectrometry detection systems. The training kits pull together many of the individual samples that are often used in demos and training classes, including reference compounds for calibration and lockmass.
.jpg)
HIC Protein Standard Mix [186007953]
The HIC Protein Standard Mix is used to evaluate and benchmark HIC columns, especially the Waters Protein-Pak™ Hi Res HIC Columns. It is recommended that this standard be used on a regular basis for evaluation of column and system performance ensuring confidence in results. It is also very valuable for method development and troubleshooting.

IEX Anion Test Standard [186006869]
The IEX Anion Test Standard is designed for use with the Waters Protein-Pak™ Hi Res IEX Columns, to allow a benchmark of the column when using anion exchange. It is recommended that this standard be used on a regular basis for benchmarking column and system performance.

IEX Cation Test Standard [186006870]
The IEX Cation Test Standard is designed for use with the Waters Protein-Pak Hi Res IEX Columns, to allow a benchmark of the column when using cation exchange. It is recommended that this standard be used on a regular basis for benchmarking column and system performance. It is a specialized set of 3 intact proteins optimized for IEX cation column chromatography.

Intact mAb Mass Check Standard [186006552]
The Intact mAb Mass Check Standard is a LC-MS standard used as a qualitative tool for intact mass analysis. This standard is designed to be used for routine MS optimization, system setup and performance testing.

MassPREP Protein Standard Mix [186004900]
The MassPREP™ Protein Standard Mix is designed for verification of HPLC/UPLC® instruments and performance of columns used for protein analysis, specfically the ACQUITY UPLC® and XBridge® BEH300 C4 Columns. This intact protein validation mix should be used on a regular basis for monitoring column and system performance. The standard is contains ribonuclease A, cytochrome c, bovine serum albumin, myoglobin, enolase, and phosphorylase B, which have a wide range of isoelectric points, molecular weights, and hydrophobicities.

ProteinWorks [coming January 2016]
Routinely achieve reproducible, accurate, and sensitive protein quantification with ProteinWorks, Waters new family of protein bioanalysis sample preparation kits. ProteinWorks eXpress Digest Kits simplify and accelerate protein digestion, streamlining and standardizing the traditionally complex pre-analytic workflow for LC-MS protein quantification via the surrogate peptide approach.

SILAC Hi3 EColi Standard [186007084]
SILAC has emerged as a very powerful method to study cell signaling, post translational modifications, protein-protein interactions, and regulation of gene expression. The quantitative SILAC Hi3 standards can be valuable in performing relative protein quantitation of mixed proteome samples, minimize interferences with the endogenous peptides and they add a second level of internal quality control.

SILAC Hi3 Phos B Standard [186007083]
SILAC has emerged as a very powerful method to study cell signaling, post translational modifications, protein-protein interactions, and regulation of gene expression. The quantitative SILAC Hi3 standards can be valuable in performing relative protein quantitation of mixed proteome samples, minimize interferences with the endogenous peptides and they add a second level of internal quality control.
.jpg)