Find Your Results


UltraPerformance Liquid Chromatography (UPLC®) combined with mass spectrometric detection (MS) is used successfully in the bioanalysis of small molecules. The small molecule consumable line provides relevant application specific standards for evaluating and running many of the Waters Omics Systems.
Analgesic Mix Standard [186006350]
The Analgesics Mix is a specialty standard developed to aid in the transfer of HPLC to UPLC methods and provides a benchmark for the system once the transfer is completed. This mix is composed of seven specifically chosen compounds that are resolved well and provide a good representative span of the chromatographic range. This mix is not only valuable to use as a validation standard for initial method transfer, it also provides the additional benefit of establishing a baseline chromatogram for the system. Therefore, it is recommended to run this mix on a regular basis after the initial method setup to continually check and compare the original benchmark chromatogram for system performance.

AutoPurification System Standard [716000765]
The AutoPurification System Standard allows the user to evaluate and benchmark the performance of an AutoPurification/Preparative System through fraction collection before analysis of critical material. This Quality Control Reference Material is specially formulated to allow the user to verify correct fraction collection. The test is highly valuable when performed at first use/installation, and any time the system has not been used or has had any changes.

Extractables & Leachables Screening Standard [186008063]
The Extractables & Leachables Screening Standard is designed to complement the Waters® Screening Platform Solution with UNIFI™. This mix is composed of 18 common polymer additives allowing users to evaluate and benchmark high resolution LC-MS systems.
The Extractables & Leachables Screening Standard covers a mass range of up to 1176 Da, supporting both positive and negative ionization modes. Compounds were specifically chosen due to stable retention times and easy evaluation of mass accuracy. Simplify your screening workflow and eliminate time consuming standard preparation steps when analyzing samples for unknown contaminants.

HILIC QC Reference Material [186007226]
The HILIC QC Reference Material is designed for use with UV and MS chromatographic systems using a HILIC column. It is intended to be used as a system benchmarking standard. When used consistently and control charted, the QC Reference Material will provide - confidence in your results - reduce troubleshooting and re-run time - enable cross lab result comparisons It is adaptable to a wide variety of separation methods.

LCMS QC Reference Standard [186006963]
The LCMS QC Reference Standard is designed for use with high performance MS's like Synapt G2-S, Xevo G-S QTof. It is intended to be used as a system benchmarking standard. When used consistently and control charted, the QCRM will provide - confidence in your results - reduce troubleshooting and re-run time - enable cross lab result comparisons The mix is extremely versatile and appropriate for a vast variety of column chemistries and dimensions. It is adaptable to a wide variety of separation methods.

MetID Small Molecule Standard Mix [186006550]
The MetID Small Molecule Standard Mix is used to test and demonstrate the Waters UNIFI® Application Solution for Metabolite Identification.

Neutrals QC Reference Material [186006360]
The Neutrals QC Reference Material is designed for use with any chromatographic systems containing a UV detector. It is intended to be used as a system benchmarking standard. The mix contains only neutral compounds. When used consistently and control charted, the QC Reference Material will provide confidence in your results, reduce troubleshooting and re-run time, and enable cross-laboratory result comparisons. This reference material is adaptable to a wide variety of separation methods.

Preparative Chromatography Mix Standard [186006703]
The Preparative Chromatography Mix Standard is a specially formulated mix for the preparative or purification system. The Preparative Chromatography Mix Standard allows the user to evaluate and benchmark their chromatography prep or purification system with UV or MS before analysis of critical material. The Preparative Chromatography Standard includes a void marker, neutral, acidic and basic compounds. It can be used with a variety of column chemistries and dimensions, and system hardware.

Reversed-Phase QC Reference Material [186006363]
The Reversed-Phase QC Reference Material is designed for use with any chromatographic systems containing a UV detector. It is intended to be used as a system benchmarking standard. The Reversed-Phase QC Reference Material is significantly more complex than the Neutrals QC Reference Material in that it contains a void marker, neutral, acidic and basic compounds which could be challenging to separate. It is designed to provide this complexity and is appropriate when complex assays are routinely performed. When used consistently and control charted, the QC Reference Material will provide - confidence in your results - reduce troubleshooting and re-run time - enable cross lab result comparisons It is adaptable to a wide variety of separation methods.