• MARKET
  • SYSTEMS
  • APPLICATIONS
  • PRODUCT TYPE
  • WATERS ADVANTAGE

Find Your Results






These complex Glycan Standards eliminate the need to prepare complex mixtures allowing for ease of use and peace of mind when running these applications. The Glycan Standards were developed to complement the Waters Glycan column and system solutions, to benchmark system performance and calibration.

2-AB Dextran Calibration Ladder [186006841]

The 2-AB Dextran Calibration Ladder was developed to help take full advantage of the BEH glycan column, to assist glycan profiling. The glycan profile obtained from UPLC-HILIC/FLR systems can be calibrated against the 2-AB labeled dextran ladder and assigned with glucose unit (GU) values. This calibration ladder provides good peak shape and reliable identification from 2 to 30 glucose units, which is twice as much as the other dextran ladder standards. This feature improves the large glycan retention time assignment.

Columns & Vials | Systems | Related Products
  • ACQUITY UPLC Glycan BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pk (186004741)
  • XBridge Glycan BEH Amide Column, 130Å, 3.5 µm, 2.1 mm X 100 mm, 1/pk (186007503)
  • TruView LCMS Certified Vials (186005666CV)

2-AB Glycan Performance Test Standard [186006349]

The 2-AB Glycan Performance Test Standard is QC verified to contain the components needed to benchmark and evaluate ACQUITY UPLC or XBridge BEH Amide Columns. This standard should be used on a regular basis for benchmarking column and system performance. It is a qualitative standard of 2-AB labeled, released glycans from Human-like IgG that are spiked with Man-5 and Man-6.

2-AB Glycan Performance Test Standard [186006349]

The 2-AB Glycan Performance Test Standard is QC verified to contain the components needed to benchmark and evaluate ACQUITY UPLC or XBridge BEH Amide Columns. This standard should be used on a regular basis for benchmarking column and system performance. It is a qualitative standard of 2-AB labeled, released glycans from Human-like IgG that are spiked with Man-5 and Man-6.

Columns & Vials | Systems | Related Products
  • ACQUITY UPLC Glycan BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pk (186004741)
  • XBridge Glycan BEH Amide Column, 130Å, 3.5 µm, 2.1 mm X 100 mm, 1/pk (186007503)
  • TruView LCMS Certified Vials (186005666CV)

2-AB Dextran Calibration Ladder [186006841]

The 2-AB Dextran Calibration Ladder was developed to help take full advantage of the BEH glycan column, to assist glycan profiling. The glycan profile obtained from UPLC-HILIC/FLR systems can be calibrated against the 2-AB labeled dextran ladder and assigned with glucose unit (GU) values. This calibration ladder provides good peak shape and reliable identification from 2 to 30 glucose units, which is twice as much as the other dextran ladder standards. This feature improves the large glycan retention time assignment.

Ammonium Formate Concentrate-Glycan Analysis [186007081]

The Ammonium Formate Concentrate is the recommended buffer that is used with the Biopharm/Glycan system, using the  ACQUITY UPLC® H-class and the ACQUITY UPLC BEH Glycan Column.

Columns & Vials | Systems | Related Products

 

  • ACQUITY UPLC Glycan BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pk (186004742)
  • ACQUITY UPLC Glycan BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pk (186004741)
  • ACQUITY UPLC Glycan BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 1/pkg (186004740)

2-AB Glycan Performance Test Standard [186006349]

The 2-AB Glycan Performance Test Standard is QC verified to contain the components needed to benchmark and evaluate ACQUITY UPLC or XBridge BEH Amide Columns. This standard should be used on a regular basis for benchmarking column and system performance. It is a qualitative standard of 2-AB labeled, released glycans from Human-like IgG that are spiked with Man-5 and Man-6.

2-AB Dextran Calibration Ladder [186006841]

The 2-AB Dextran Calibration Ladder was developed to help take full advantage of the BEH glycan column, to assist glycan profiling. The glycan profile obtained from UPLC-HILIC/FLR systems can be calibrated against the 2-AB labeled dextran ladder and assigned with glucose unit (GU) values. This calibration ladder provides good peak shape and reliable identification from 2 to 30 glucose units, which is twice as much as the other dextran ladder standards. This feature improves the large glycan retention time assignment.

Fluorescence Detector Standard [700003694]

The Fluorescence Detector Standard is intended to be used for system assessment of an Alliance® HPLC with Fluorescence Detector. This kit is designed for use by a Waters certified engineer or user as part of a performance maintenance or qualification activity.  Protocols in the use of this kit are available via the purchase of Waters qualification services or self directed qualification training and license.  

Glycoprotein Performance Test Standard [186008010]

The Waters Glycoprotein Performance Test Standard is a formulation of a glycosylated and high mannose glycoforms of ribonuclease (RNase).  It is intended for use as a material to condition and monitor the performance of ACQUITY UPLC Glycoprotein BEH Amide 300Å 1.7 μm Columns.  
 
Reconstitute the contents of each vial with 25 μL of 0.1% TFA in 80% ACN.  For conditioning a previously unused 2.1 mm I.D. ACQUITY UPLC Glycoprotein BEH Amide 300Å 1.7 μm Column, perform two sequential gradient separations of the standard injected at a volume of 10 μL.  
Columns & Vials | Related Products

ACQUITY UPLC Glycoprotein BEH Amide 300Å 1.7 μm columns

GlycoWorks RapiFluor-MS N-Glycan Kit - 96 Samples [176003606]

The GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response.

GlycoWorks RapiFluor-MS N-Glycan Kit Starter Kit [176003635]

The GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response. Now you can use a single label that provides valuable information from characterization to routine monitoring. 

GlycoWorks RapiFluor-MS N-Glycan Kit - 24 Samples [176003712]

Re-imagine a streamlined, fast, and highly sensitive way to analyze released N-glycans. With just 3 easy steps in 30 minutes, the GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response. Now you can use a single label that provides valuable information from characterization to routine monitoring. Glycan analysis just got easier and more sensitive.

GlycoWorks Control Standard [186007033]

The GlycoWorks Control Standard is used for validation and troubleshooting when using the GlycoWorks High-throughput or Single Use kits. It is an undigested, unlabeled, Human IgG standard. When purchasing the GlycoWorks Single Use Sample Preparation Kit or the GlycoWorks High-throughput Sample Preparation Kit, this standard is included but can also be purchased separately.

Columns & Vials | Related Products
  • ACQUITY UPLC Glycan BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pk (186004741)
  • XBridge Glycan BEH Amide Column, 130Å, 3.5 µm, 2.1 mm X 100 mm, 1/pk (186007503)
  • TruView LCMS Certified Vials (186005666CV)

GlycoWorks High-throughput Prep Kit [176003090]

The GlycoWorks High-throughput Sample Preparation Kit works synergistically with Waters ACQUITY UPLC Glycan Application Solution to generate high quality data from the analyses of pre-column derivatized, labeled N-glycans. A key component of this offering is Waters HILIC Solid-Phase Extraction (SPE) plate for separation of released glycans from the protein and for the subsequent separation of the labeled glycans from the free excess label. This kit can process 48 samples.

GlycoWorks Single Use Prep Kit [176003119]

The GlycoWorks Single Use Sample Preparation Kit was developed and rigorously tested to synergistically work with our existing ACQUITY UPLC Glycan Application Solution for the generation of high quality data from the analyses or pre-column derivatized, labeled N-glycans. A key component of this offering involves the use of Waters HILIC solid-phase extraction (SPE) material for the separation of released glycans from the protein and for the subsequent separation of the labeled glycans from the free excess label. This kit can process 10 samples.

2-AB Glycan Performance Test Standard [186006349]

The 2-AB Glycan Performance Test Standard is QC verified to contain the components needed to benchmark and evaluate ACQUITY UPLC or XBridge BEH Amide Columns. This standard should be used on a regular basis for benchmarking column and system performance. It is a qualitative standard of 2-AB labeled, released glycans from Human-like IgG that are spiked with Man-5 and Man-6.

GlycoWorks High-throughput Prep Kit [176003090]

The GlycoWorks High-throughput Sample Preparation Kit works synergistically with Waters ACQUITY UPLC Glycan Application Solution to generate high quality data from the analyses of pre-column derivatized, labeled N-glycans. A key component of this offering is Waters HILIC Solid-Phase Extraction (SPE) plate for separation of released glycans from the protein and for the subsequent separation of the labeled glycans from the free excess label. This kit can process 48 samples.

Columns & Vials | Related Products
  • ACQUITY UPLC Glycan BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pk (186004741)
  • XBridge Glycan BEH Amide Column, 130Å, 3.5 µm, 2.1 mm X 100 mm, 1/pk (186007503)
  • TruView LCMS Certified Vials (186005666CV)

GlycoWorks Single Use Prep Kit [176003119]

The GlycoWorks Single Use Sample Preparation Kit was developed and rigorously tested to synergistically work with our existing ACQUITY UPLC Glycan Application Solution for the generation of high quality data from the analyses or pre-column derivatized, labeled N-glycans. A key component of this offering involves the use of Waters HILIC solid-phase extraction (SPE) material for the separation of released glycans from the protein and for the subsequent separation of the labeled glycans from the free excess label. This kit can process 10 samples.

GlycoWorks HILIC 96-well Plate, 1/pk [186002780]

The GlycoWorks HILIC 96-well Plate is a key component of the GlycoWorks Sample Preparation offering. The HILIC solid-phase extraction (SPE) material is used and tested for the separation of released glycans from the protein and for the subsequent separation of the labeled glycans from the free excess label.

2-AB Glycan Performance Test Standard [186006349]

The 2-AB Glycan Performance Test Standard is QC verified to contain the components needed to benchmark and evaluate ACQUITY UPLC or XBridge BEH Amide Columns. This standard should be used on a regular basis for benchmarking column and system performance. It is a qualitative standard of 2-AB labeled, released glycans from Human-like IgG that are spiked with Man-5 and Man-6.

2-AB Dextran Calibration Ladder [186006841]

The 2-AB Dextran Calibration Ladder was developed to help take full advantage of the BEH glycan column, to assist glycan profiling. The glycan profile obtained from UPLC-HILIC/FLR systems can be calibrated against the 2-AB labeled dextran ladder and assigned with glucose unit (GU) values. This calibration ladder provides good peak shape and reliable identification from 2 to 30 glucose units, which is twice as much as the other dextran ladder standards. This feature improves the large glycan retention time assignment.

GlycoWorks Control Standard [186007033]

The GlycoWorks Control Standard is used for validation and troubleshooting when using the GlycoWorks High-throughput or Single Use kits. It is an undigested, unlabeled, Human IgG standard. When purchasing the GlycoWorks Single Use Sample Preparation Kit or the GlycoWorks High-throughput Sample Preparation Kit, this standard is included but can also be purchased separately.

GlycoWorks Reagent Kit [186007034]

The GlycoWorks Reagent Kit is provides reagents needed for both digestion and labeling reactions to follow the GlycoWorks High-throughput or Single Use Kit protocols. This kit is sold as a refill for use with the GlycoWorks Single Use Sample Preparation Kit or the GlycoWorks High-throughput Sample Preparation Kit. 

GlycoWorks HILIC 1 cc Catridge, 20/pk [186007080]

The GlycoWorks HILIC 1 cc Cartridge Pack is dual purpose; the catridges can be used for both the extraction of glycans as well as the removal of excess labeling reagent. Each pack contains 20, 1 cc cartridges for a total of 10 reactions for low sample volume environments following the GlycoWorks Single Use protocol.

GlycoWorks HILIC 1 cc Flangeless Catridge [186007239]

The GlycoWorks HILIC 1 cc Flangeless Cartridge Pack is dual purpose; the cartidges can be used for both the extraction of glycans as well as the removal of excess labeling reagent. The flangeless version is designed specifically for customers who use the positive pressure manifold (PPM).

GlycoWorks HILIC 1 cc Catridge, 20/pk [186007080]

The GlycoWorks HILIC 1 cc Cartridge Pack is dual purpose; the catridges can be used for both the extraction of glycans as well as the removal of excess labeling reagent. Each pack contains 20, 1 cc cartridges for a total of 10 reactions for low sample volume environments following the GlycoWorks Single Use protocol.

Columns & Vials | Related Products
  • ACQUITY UPLC Glycan BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pk (186004741)
  • XBridge Glycan BEH Amide Column, 130Å, 3.5 µm, 2.1 mm X 100 mm, 1/pk (186007503)

GlycoWorks High-throughput Prep Kit [176003090]

The GlycoWorks High-throughput Sample Preparation Kit works synergistically with Waters ACQUITY UPLC Glycan Application Solution to generate high quality data from the analyses of pre-column derivatized, labeled N-glycans. A key component of this offering is Waters HILIC Solid-Phase Extraction (SPE) plate for separation of released glycans from the protein and for the subsequent separation of the labeled glycans from the free excess label. This kit can process 48 samples.

GlycoWorks Single Use Prep Kit [176003119]

The GlycoWorks Single Use Sample Preparation Kit was developed and rigorously tested to synergistically work with our existing ACQUITY UPLC Glycan Application Solution for the generation of high quality data from the analyses or pre-column derivatized, labeled N-glycans. A key component of this offering involves the use of Waters HILIC solid-phase extraction (SPE) material for the separation of released glycans from the protein and for the subsequent separation of the labeled glycans from the free excess label. This kit can process 10 samples.

2-AB Glycan Performance Test Standard [186006349]

The 2-AB Glycan Performance Test Standard is QC verified to contain the components needed to benchmark and evaluate ACQUITY UPLC or XBridge BEH Amide Columns. This standard should be used on a regular basis for benchmarking column and system performance. It is a qualitative standard of 2-AB labeled, released glycans from Human-like IgG that are spiked with Man-5 and Man-6.

GlycoWorks HILIC 1 cc Flangeless Catridge [186007239]

The GlycoWorks HILIC 1 cc Flangeless Cartridge Pack is dual purpose; the cartidges can be used for both the extraction of glycans as well as the removal of excess labeling reagent. The flangeless version is designed specifically for customers who use the positive pressure manifold (PPM).

Columns & Vials | Related Products
  • ACQUITY UPLC Glycan BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pk (186004741)
  • XBridge Glycan BEH Amide Column, 130Å, 3.5 µm, 2.1 mm X 100 mm, 1/pk (186007503)

GlycoWorks High-throughput Prep Kit [176003090]

The GlycoWorks High-throughput Sample Preparation Kit works synergistically with Waters ACQUITY UPLC Glycan Application Solution to generate high quality data from the analyses of pre-column derivatized, labeled N-glycans. A key component of this offering is Waters HILIC Solid-Phase Extraction (SPE) plate for separation of released glycans from the protein and for the subsequent separation of the labeled glycans from the free excess label. This kit can process 48 samples.

GlycoWorks Single Use Prep Kit [176003119]

The GlycoWorks Single Use Sample Preparation Kit was developed and rigorously tested to synergistically work with our existing ACQUITY UPLC Glycan Application Solution for the generation of high quality data from the analyses or pre-column derivatized, labeled N-glycans. A key component of this offering involves the use of Waters HILIC solid-phase extraction (SPE) material for the separation of released glycans from the protein and for the subsequent separation of the labeled glycans from the free excess label. This kit can process 10 samples.

GlycoWorks Control Standard [186007033]

The GlycoWorks Control Standard is used for validation and troubleshooting when using the GlycoWorks High-throughput or Single Use kits. It is an undigested, unlabeled, Human IgG standard. When purchasing the GlycoWorks Single Use Sample Preparation Kit or the GlycoWorks High-throughput Sample Preparation Kit, this standard is included but can also be purchased separately.

GlycoWorks Reagent Kit [186007034]

The GlycoWorks Reagent Kit is provides reagents needed for both digestion and labeling reactions to follow the GlycoWorks High-throughput or Single Use Kit protocols. This kit is sold as a refill for use with the GlycoWorks Single Use Sample Preparation Kit or the GlycoWorks High-throughput Sample Preparation Kit. 

GlycoWorks HILIC 1 cc Catridge, 20/pk [186007080]

The GlycoWorks HILIC 1 cc Cartridge Pack is dual purpose; the catridges can be used for both the extraction of glycans as well as the removal of excess labeling reagent. Each pack contains 20, 1 cc cartridges for a total of 10 reactions for low sample volume environments following the GlycoWorks Single Use protocol.

GlycoWorks HILIC 96-well Plate, 1/pk [186002780]

The GlycoWorks HILIC 96-well Plate is a key component of the GlycoWorks Sample Preparation offering. The HILIC solid-phase extraction (SPE) material is used and tested for the separation of released glycans from the protein and for the subsequent separation of the labeled glycans from the free excess label.

Columns & Vials | Related Products

GlycoWorks High-throughput Prep Kit [176003090]

The GlycoWorks High-throughput Sample Preparation Kit works synergistically with Waters ACQUITY UPLC Glycan Application Solution to generate high quality data from the analyses of pre-column derivatized, labeled N-glycans. A key component of this offering is Waters HILIC Solid-Phase Extraction (SPE) plate for separation of released glycans from the protein and for the subsequent separation of the labeled glycans from the free excess label. This kit can process 48 samples.

GlycoWorks Single Use Prep Kit [176003119]

The GlycoWorks Single Use Sample Preparation Kit was developed and rigorously tested to synergistically work with our existing ACQUITY UPLC Glycan Application Solution for the generation of high quality data from the analyses or pre-column derivatized, labeled N-glycans. A key component of this offering involves the use of Waters HILIC solid-phase extraction (SPE) material for the separation of released glycans from the protein and for the subsequent separation of the labeled glycans from the free excess label. This kit can process 10 samples.

GlycoWorks Control Standard [186007033]

The GlycoWorks Control Standard is used for validation and troubleshooting when using the GlycoWorks High-throughput or Single Use kits. It is an undigested, unlabeled, Human IgG standard. When purchasing the GlycoWorks Single Use Sample Preparation Kit or the GlycoWorks High-throughput Sample Preparation Kit, this standard is included but can also be purchased separately.

GlycoWorks High-throughput Prep Kit [176003090]

The GlycoWorks High-throughput Sample Preparation Kit works synergistically with Waters ACQUITY UPLC Glycan Application Solution to generate high quality data from the analyses of pre-column derivatized, labeled N-glycans. A key component of this offering is Waters HILIC Solid-Phase Extraction (SPE) plate for separation of released glycans from the protein and for the subsequent separation of the labeled glycans from the free excess label. This kit can process 48 samples.

GlycoWorks Single Use Prep Kit [176003119]

The GlycoWorks Single Use Sample Preparation Kit was developed and rigorously tested to synergistically work with our existing ACQUITY UPLC Glycan Application Solution for the generation of high quality data from the analyses or pre-column derivatized, labeled N-glycans. A key component of this offering involves the use of Waters HILIC solid-phase extraction (SPE) material for the separation of released glycans from the protein and for the subsequent separation of the labeled glycans from the free excess label. This kit can process 10 samples.

RapiGest SF, 1 mg, 1/pk [186001860]

RapiGest SF, is a patented anionic surfactant that drastically improves in-gel and in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis to minimize high background noise often seen from other common surfactants. Add RapiGest SF to your proteolytic digestion, (using trypsin or other enzymes) to enhance digestion speed and increase peptide recovery. 

RapiGest SF, 1 mg , 5/pk [186001861]

RapiGest SF, is a patented anionic surfactant that drastically improves in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis by avoiding high background noise often seen from other common surfactants. Add RapiGest SF to your proteolytic digestion, (using trypsin or other enzymes) to enhance digestion speed and increase peptide recovery.

RapiGest SF, 50 mg, 1/pk [186002122]

RapiGest SF, is a patented anionic surfactant that drastically improves in-gel and in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis to minimize high background noise often seen from other common surfactants. Add RapiGest SF to your proteolytic digestion, (using trypsin or other enzymes) to enhance digestion speed and increase peptide recovery. 

RapiGest SF, 10 mg, 1/pk [186002123]

RapiGest SF, is a patented anionic surfactant that drastically improves in-gel and in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis to minimize high background noise often seen from other common surfactants. Add RapiGest SF to your proteolytic digestion, (using trypsin or other enzymes) to enhance digestion speed and increase peptide recovery. 

GlycoWorks HILIC 96-well Plate, 1/pk [186002780]

The GlycoWorks HILIC 96-well Plate is a key component of the GlycoWorks Sample Preparation offering. The HILIC solid-phase extraction (SPE) material is used and tested for the separation of released glycans from the protein and for the subsequent separation of the labeled glycans from the free excess label.

GlycoWorks Control Standard [186007033]

The GlycoWorks Control Standard is used for validation and troubleshooting when using the GlycoWorks High-throughput or Single Use kits. It is an undigested, unlabeled, Human IgG standard. When purchasing the GlycoWorks Single Use Sample Preparation Kit or the GlycoWorks High-throughput Sample Preparation Kit, this standard is included but can also be purchased separately.

GlycoWorks Reagent Kit [186007034]

The GlycoWorks Reagent Kit is provides reagents needed for both digestion and labeling reactions to follow the GlycoWorks High-throughput or Single Use Kit protocols. This kit is sold as a refill for use with the GlycoWorks Single Use Sample Preparation Kit or the GlycoWorks High-throughput Sample Preparation Kit. 

GlycoWorks HILIC 1 cc Catridge, 20/pk [186007080]

The GlycoWorks HILIC 1 cc Cartridge Pack is dual purpose; the catridges can be used for both the extraction of glycans as well as the removal of excess labeling reagent. Each pack contains 20, 1 cc cartridges for a total of 10 reactions for low sample volume environments following the GlycoWorks Single Use protocol.

GlycoWorks HILIC 1 cc Flangeless Catridge [186007239]

The GlycoWorks HILIC 1 cc Flangeless Cartridge Pack is dual purpose; the cartidges can be used for both the extraction of glycans as well as the removal of excess labeling reagent. The flangeless version is designed specifically for customers who use the positive pressure manifold (PPM).

GlycoWorks RapiFluor-MS N-Glycan Kit - 96 Samples [176003606]

The GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response.

GlycoWorks RapiFluor-MS N-Glycan Kit Starter Kit [176003635]

The GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response. Now you can use a single label that provides valuable information from characterization to routine monitoring. 

RapiFluor-MS Glycan Performance Test Standard [186007983]

The RapiFluor-MS Glycan Performance Test Standard is intended to be used as a benchmarking standard and labeled, complex control to compliment the GlycoWorks RapiFluor-MS N-Glycan Kit solution. 

RapiFluor-MS Dextran Calibration Ladder [186007982]

The RapiFluor-MS Dextran Calibration Ladder was developed to help take full advantage of the BEH glycan column, to assist glycan profiling. The glycan profile obtained from UPLC-HILIC/FLR systems can be calibrated against the RapiFluor-MS-labeled dextran ladder and assigned with glucose unit (GU) values. 

GlycoWorks RapiFluor-MS N-Glycan Kit - 24 Samples [176003712]

Re-imagine a streamlined, fast, and highly sensitive way to analyze released N-glycans. With just 3 easy steps in 30 minutes, the GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response. Now you can use a single label that provides valuable information from characterization to routine monitoring. Glycan analysis just got easier and more sensitive.

RapiGest SF, 3 mg, 1/pk [186008090]

RapiGest SF, is a patented anionic surfactant that drastically improves in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis by avoiding high background noise often seen from other common surfactants.

GlycoWorks Rapid Deglycosylation Kit 3x8 [176003868]

GlycoWorks Rapid Deglycosylation Kit 1x24 [176003867]

GlycoWorks SPE Reagents [186007992]

LC-MS

GlycoWorks High-throughput Prep Kit [176003090]

The GlycoWorks High-throughput Sample Preparation Kit works synergistically with Waters ACQUITY UPLC Glycan Application Solution to generate high quality data from the analyses of pre-column derivatized, labeled N-glycans. A key component of this offering is Waters HILIC Solid-Phase Extraction (SPE) plate for separation of released glycans from the protein and for the subsequent separation of the labeled glycans from the free excess label. This kit can process 48 samples.

GlycoWorks Single Use Prep Kit [176003119]

The GlycoWorks Single Use Sample Preparation Kit was developed and rigorously tested to synergistically work with our existing ACQUITY UPLC Glycan Application Solution for the generation of high quality data from the analyses or pre-column derivatized, labeled N-glycans. A key component of this offering involves the use of Waters HILIC solid-phase extraction (SPE) material for the separation of released glycans from the protein and for the subsequent separation of the labeled glycans from the free excess label. This kit can process 10 samples.

RapiGest SF, 1 mg, 1/pk [186001860]

RapiGest SF, is a patented anionic surfactant that drastically improves in-gel and in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis to minimize high background noise often seen from other common surfactants. Add RapiGest SF to your proteolytic digestion, (using trypsin or other enzymes) to enhance digestion speed and increase peptide recovery. 

RapiGest SF, 1 mg , 5/pk [186001861]

RapiGest SF, is a patented anionic surfactant that drastically improves in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis by avoiding high background noise often seen from other common surfactants. Add RapiGest SF to your proteolytic digestion, (using trypsin or other enzymes) to enhance digestion speed and increase peptide recovery.

RapiGest SF, 50 mg, 1/pk [186002122]

RapiGest SF, is a patented anionic surfactant that drastically improves in-gel and in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis to minimize high background noise often seen from other common surfactants. Add RapiGest SF to your proteolytic digestion, (using trypsin or other enzymes) to enhance digestion speed and increase peptide recovery. 

RapiGest SF, 10 mg, 1/pk [186002123]

RapiGest SF, is a patented anionic surfactant that drastically improves in-gel and in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis to minimize high background noise often seen from other common surfactants. Add RapiGest SF to your proteolytic digestion, (using trypsin or other enzymes) to enhance digestion speed and increase peptide recovery. 

GlycoWorks HILIC 96-well Plate, 1/pk [186002780]

The GlycoWorks HILIC 96-well Plate is a key component of the GlycoWorks Sample Preparation offering. The HILIC solid-phase extraction (SPE) material is used and tested for the separation of released glycans from the protein and for the subsequent separation of the labeled glycans from the free excess label.

GlycoWorks Control Standard [186007033]

The GlycoWorks Control Standard is used for validation and troubleshooting when using the GlycoWorks High-throughput or Single Use kits. It is an undigested, unlabeled, Human IgG standard. When purchasing the GlycoWorks Single Use Sample Preparation Kit or the GlycoWorks High-throughput Sample Preparation Kit, this standard is included but can also be purchased separately.

GlycoWorks Reagent Kit [186007034]

The GlycoWorks Reagent Kit is provides reagents needed for both digestion and labeling reactions to follow the GlycoWorks High-throughput or Single Use Kit protocols. This kit is sold as a refill for use with the GlycoWorks Single Use Sample Preparation Kit or the GlycoWorks High-throughput Sample Preparation Kit. 

GlycoWorks HILIC 1 cc Catridge, 20/pk [186007080]

The GlycoWorks HILIC 1 cc Cartridge Pack is dual purpose; the catridges can be used for both the extraction of glycans as well as the removal of excess labeling reagent. Each pack contains 20, 1 cc cartridges for a total of 10 reactions for low sample volume environments following the GlycoWorks Single Use protocol.

GlycoWorks HILIC 1 cc Flangeless Catridge [186007239]

The GlycoWorks HILIC 1 cc Flangeless Cartridge Pack is dual purpose; the cartidges can be used for both the extraction of glycans as well as the removal of excess labeling reagent. The flangeless version is designed specifically for customers who use the positive pressure manifold (PPM).

GlycoWorks RapiFluor-MS N-Glycan Kit - 96 Samples [176003606]

The GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response.

GlycoWorks RapiFluor-MS N-Glycan Kit Starter Kit [176003635]

The GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response. Now you can use a single label that provides valuable information from characterization to routine monitoring. 

RapiFluor-MS Glycan Performance Test Standard [186007983]

The RapiFluor-MS Glycan Performance Test Standard is intended to be used as a benchmarking standard and labeled, complex control to compliment the GlycoWorks RapiFluor-MS N-Glycan Kit solution. 

RapiFluor-MS Dextran Calibration Ladder [186007982]

The RapiFluor-MS Dextran Calibration Ladder was developed to help take full advantage of the BEH glycan column, to assist glycan profiling. The glycan profile obtained from UPLC-HILIC/FLR systems can be calibrated against the RapiFluor-MS-labeled dextran ladder and assigned with glucose unit (GU) values. 

GlycoWorks RapiFluor-MS N-Glycan Kit - 24 Samples [176003712]

Re-imagine a streamlined, fast, and highly sensitive way to analyze released N-glycans. With just 3 easy steps in 30 minutes, the GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response. Now you can use a single label that provides valuable information from characterization to routine monitoring. Glycan analysis just got easier and more sensitive.

RapiGest SF, 3 mg, 1/pk [186008090]

RapiGest SF, is a patented anionic surfactant that drastically improves in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis by avoiding high background noise often seen from other common surfactants.

GlycoWorks Rapid Deglycosylation Kit 3x8 [176003868]

LC-MS

GlycoWorks High-throughput Prep Kit [176003090]

The GlycoWorks High-throughput Sample Preparation Kit works synergistically with Waters ACQUITY UPLC Glycan Application Solution to generate high quality data from the analyses of pre-column derivatized, labeled N-glycans. A key component of this offering is Waters HILIC Solid-Phase Extraction (SPE) plate for separation of released glycans from the protein and for the subsequent separation of the labeled glycans from the free excess label. This kit can process 48 samples.

GlycoWorks Single Use Prep Kit [176003119]

The GlycoWorks Single Use Sample Preparation Kit was developed and rigorously tested to synergistically work with our existing ACQUITY UPLC Glycan Application Solution for the generation of high quality data from the analyses or pre-column derivatized, labeled N-glycans. A key component of this offering involves the use of Waters HILIC solid-phase extraction (SPE) material for the separation of released glycans from the protein and for the subsequent separation of the labeled glycans from the free excess label. This kit can process 10 samples.

RapiGest SF, 1 mg, 1/pk [186001860]

RapiGest SF, is a patented anionic surfactant that drastically improves in-gel and in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis to minimize high background noise often seen from other common surfactants. Add RapiGest SF to your proteolytic digestion, (using trypsin or other enzymes) to enhance digestion speed and increase peptide recovery. 

RapiGest SF, 1 mg , 5/pk [186001861]

RapiGest SF, is a patented anionic surfactant that drastically improves in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis by avoiding high background noise often seen from other common surfactants. Add RapiGest SF to your proteolytic digestion, (using trypsin or other enzymes) to enhance digestion speed and increase peptide recovery.

RapiGest SF, 50 mg, 1/pk [186002122]

RapiGest SF, is a patented anionic surfactant that drastically improves in-gel and in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis to minimize high background noise often seen from other common surfactants. Add RapiGest SF to your proteolytic digestion, (using trypsin or other enzymes) to enhance digestion speed and increase peptide recovery. 

RapiGest SF, 10 mg, 1/pk [186002123]

RapiGest SF, is a patented anionic surfactant that drastically improves in-gel and in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis to minimize high background noise often seen from other common surfactants. Add RapiGest SF to your proteolytic digestion, (using trypsin or other enzymes) to enhance digestion speed and increase peptide recovery. 

GlycoWorks HILIC 96-well Plate, 1/pk [186002780]

The GlycoWorks HILIC 96-well Plate is a key component of the GlycoWorks Sample Preparation offering. The HILIC solid-phase extraction (SPE) material is used and tested for the separation of released glycans from the protein and for the subsequent separation of the labeled glycans from the free excess label.

GlycoWorks Control Standard [186007033]

The GlycoWorks Control Standard is used for validation and troubleshooting when using the GlycoWorks High-throughput or Single Use kits. It is an undigested, unlabeled, Human IgG standard. When purchasing the GlycoWorks Single Use Sample Preparation Kit or the GlycoWorks High-throughput Sample Preparation Kit, this standard is included but can also be purchased separately.

GlycoWorks Reagent Kit [186007034]

The GlycoWorks Reagent Kit is provides reagents needed for both digestion and labeling reactions to follow the GlycoWorks High-throughput or Single Use Kit protocols. This kit is sold as a refill for use with the GlycoWorks Single Use Sample Preparation Kit or the GlycoWorks High-throughput Sample Preparation Kit. 

GlycoWorks HILIC 1 cc Catridge, 20/pk [186007080]

The GlycoWorks HILIC 1 cc Cartridge Pack is dual purpose; the catridges can be used for both the extraction of glycans as well as the removal of excess labeling reagent. Each pack contains 20, 1 cc cartridges for a total of 10 reactions for low sample volume environments following the GlycoWorks Single Use protocol.

GlycoWorks HILIC 1 cc Flangeless Catridge [186007239]

The GlycoWorks HILIC 1 cc Flangeless Cartridge Pack is dual purpose; the cartidges can be used for both the extraction of glycans as well as the removal of excess labeling reagent. The flangeless version is designed specifically for customers who use the positive pressure manifold (PPM).

GlycoWorks RapiFluor-MS N-Glycan Kit - 96 Samples [176003606]

The GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response.

GlycoWorks RapiFluor-MS N-Glycan Kit Starter Kit [176003635]

The GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response. Now you can use a single label that provides valuable information from characterization to routine monitoring. 

RapiFluor-MS Glycan Performance Test Standard [186007983]

The RapiFluor-MS Glycan Performance Test Standard is intended to be used as a benchmarking standard and labeled, complex control to compliment the GlycoWorks RapiFluor-MS N-Glycan Kit solution. 

RapiFluor-MS Dextran Calibration Ladder [186007982]

The RapiFluor-MS Dextran Calibration Ladder was developed to help take full advantage of the BEH glycan column, to assist glycan profiling. The glycan profile obtained from UPLC-HILIC/FLR systems can be calibrated against the RapiFluor-MS-labeled dextran ladder and assigned with glucose unit (GU) values. 

GlycoWorks RapiFluor-MS N-Glycan Kit - 24 Samples [176003712]

Re-imagine a streamlined, fast, and highly sensitive way to analyze released N-glycans. With just 3 easy steps in 30 minutes, the GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response. Now you can use a single label that provides valuable information from characterization to routine monitoring. Glycan analysis just got easier and more sensitive.

RapiGest SF, 3 mg, 1/pk [186008090]

RapiGest SF, is a patented anionic surfactant that drastically improves in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis by avoiding high background noise often seen from other common surfactants.

Glycoworks RapiFluor-MS N-Glycan Basic Kit-24 sample [176003911]

The GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response.

Columns & Vials | Systems | Related Products
  • ACQUITY UPLC Glycan BEH Amide 130Å, 1.7 μm, 2.1 x 50 mm (p/n 186004740)
  • ACQUITY UPLC Glycan BEH Amide 130Å, 1.7 μm, 2.1 x 150 mm (p/n 186004742)
  • XBridge Glycan BEH Amide XP, 130Å, 2.5 μm, 2.1 x 50 mm (p/n 186007263)
  • XBridge Glycan BEH Amide XP, 130Å, 2.5 μm, 2.1 x 150 mm (p/n 186007265)

GlycoWorks High-throughput Prep Kit [176003090]

The GlycoWorks High-throughput Sample Preparation Kit works synergistically with Waters ACQUITY UPLC Glycan Application Solution to generate high quality data from the analyses of pre-column derivatized, labeled N-glycans. A key component of this offering is Waters HILIC Solid-Phase Extraction (SPE) plate for separation of released glycans from the protein and for the subsequent separation of the labeled glycans from the free excess label. This kit can process 48 samples.

GlycoWorks Single Use Prep Kit [176003119]

The GlycoWorks Single Use Sample Preparation Kit was developed and rigorously tested to synergistically work with our existing ACQUITY UPLC Glycan Application Solution for the generation of high quality data from the analyses or pre-column derivatized, labeled N-glycans. A key component of this offering involves the use of Waters HILIC solid-phase extraction (SPE) material for the separation of released glycans from the protein and for the subsequent separation of the labeled glycans from the free excess label. This kit can process 10 samples.

RapiGest SF, 1 mg, 1/pk [186001860]

RapiGest SF, is a patented anionic surfactant that drastically improves in-gel and in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis to minimize high background noise often seen from other common surfactants. Add RapiGest SF to your proteolytic digestion, (using trypsin or other enzymes) to enhance digestion speed and increase peptide recovery. 

RapiGest SF, 1 mg , 5/pk [186001861]

RapiGest SF, is a patented anionic surfactant that drastically improves in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis by avoiding high background noise often seen from other common surfactants. Add RapiGest SF to your proteolytic digestion, (using trypsin or other enzymes) to enhance digestion speed and increase peptide recovery.

RapiGest SF, 50 mg, 1/pk [186002122]

RapiGest SF, is a patented anionic surfactant that drastically improves in-gel and in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis to minimize high background noise often seen from other common surfactants. Add RapiGest SF to your proteolytic digestion, (using trypsin or other enzymes) to enhance digestion speed and increase peptide recovery. 

RapiGest SF, 10 mg, 1/pk [186002123]

RapiGest SF, is a patented anionic surfactant that drastically improves in-gel and in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis to minimize high background noise often seen from other common surfactants. Add RapiGest SF to your proteolytic digestion, (using trypsin or other enzymes) to enhance digestion speed and increase peptide recovery. 

GlycoWorks HILIC 96-well Plate, 1/pk [186002780]

The GlycoWorks HILIC 96-well Plate is a key component of the GlycoWorks Sample Preparation offering. The HILIC solid-phase extraction (SPE) material is used and tested for the separation of released glycans from the protein and for the subsequent separation of the labeled glycans from the free excess label.

Intact mAb Mass Check Standard [186006552]

The Intact mAb Mass Check Standard is a LC-MS standard used as a qualitative tool for intact mass analysis. This standard is designed to be used for routine MS optimization, system setup and performance testing.

GlycoWorks Control Standard [186007033]

The GlycoWorks Control Standard is used for validation and troubleshooting when using the GlycoWorks High-throughput or Single Use kits. It is an undigested, unlabeled, Human IgG standard. When purchasing the GlycoWorks Single Use Sample Preparation Kit or the GlycoWorks High-throughput Sample Preparation Kit, this standard is included but can also be purchased separately.

GlycoWorks Reagent Kit [186007034]

The GlycoWorks Reagent Kit is provides reagents needed for both digestion and labeling reactions to follow the GlycoWorks High-throughput or Single Use Kit protocols. This kit is sold as a refill for use with the GlycoWorks Single Use Sample Preparation Kit or the GlycoWorks High-throughput Sample Preparation Kit. 

GlycoWorks HILIC 1 cc Catridge, 20/pk [186007080]

The GlycoWorks HILIC 1 cc Cartridge Pack is dual purpose; the catridges can be used for both the extraction of glycans as well as the removal of excess labeling reagent. Each pack contains 20, 1 cc cartridges for a total of 10 reactions for low sample volume environments following the GlycoWorks Single Use protocol.

GlycoWorks HILIC 1 cc Flangeless Catridge [186007239]

The GlycoWorks HILIC 1 cc Flangeless Cartridge Pack is dual purpose; the cartidges can be used for both the extraction of glycans as well as the removal of excess labeling reagent. The flangeless version is designed specifically for customers who use the positive pressure manifold (PPM).

GlycoWorks RapiFluor-MS N-Glycan Kit - 96 Samples [176003606]

The GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response.

GlycoWorks RapiFluor-MS N-Glycan Kit Starter Kit [176003635]

The GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response. Now you can use a single label that provides valuable information from characterization to routine monitoring. 

RapiFluor-MS Glycan Performance Test Standard [186007983]

The RapiFluor-MS Glycan Performance Test Standard is intended to be used as a benchmarking standard and labeled, complex control to compliment the GlycoWorks RapiFluor-MS N-Glycan Kit solution. 

RapiFluor-MS Dextran Calibration Ladder [186007982]

The RapiFluor-MS Dextran Calibration Ladder was developed to help take full advantage of the BEH glycan column, to assist glycan profiling. The glycan profile obtained from UPLC-HILIC/FLR systems can be calibrated against the RapiFluor-MS-labeled dextran ladder and assigned with glucose unit (GU) values. 

GlycoWorks RapiFluor-MS N-Glycan Kit - 24 Samples [176003712]

Re-imagine a streamlined, fast, and highly sensitive way to analyze released N-glycans. With just 3 easy steps in 30 minutes, the GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response. Now you can use a single label that provides valuable information from characterization to routine monitoring. Glycan analysis just got easier and more sensitive.

Glycoprotein Performance Test Standard [186008010]

The Waters Glycoprotein Performance Test Standard is a formulation of a glycosylated and high mannose glycoforms of ribonuclease (RNase).  It is intended for use as a material to condition and monitor the performance of ACQUITY UPLC Glycoprotein BEH Amide 300Å 1.7 μm Columns.  
 
Reconstitute the contents of each vial with 25 μL of 0.1% TFA in 80% ACN.  For conditioning a previously unused 2.1 mm I.D. ACQUITY UPLC Glycoprotein BEH Amide 300Å 1.7 μm Column, perform two sequential gradient separations of the standard injected at a volume of 10 μL.  

RapiGest SF, 3 mg, 1/pk [186008090]

RapiGest SF, is a patented anionic surfactant that drastically improves in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis by avoiding high background noise often seen from other common surfactants.

GlycoWorks Rapid Deglycosylation Kit 3x8 [176003868]

GlycoWorks Rapid Deglycosylation Kit 1x24 [176003867]

GlycoWorks SPE Reagents [186007992]

GlycoWorks Rapid Buffer, 5 mL [186008100]

Glycoworks RapiFluor-MS N-Glycan Kit-24 sample [176003713]

Re-imagine a streamlined, fast, and highly sensitive way to analyze released N-glycans. With just 3 easy steps in 30 minutes, the GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response. Now you can use a single label that provides valuable information from characterization to routine monitoring. Glycan analysis just got easier and more sensitive.

Glycoworks RapiFluor-MS N-Glycan Refill Kit-24 sample [176003714]

Glycoworks Sample Collection Module [186007988]

Glycoworks RapiFluor-MS N-Glycan Basic Kit-96 sample [176003910]

The GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response.

Glycoworks RapiFluor-MS N-Glycan Basic Kit-96 sample [176003910]

The GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response.

Columns & Vials | Systems | Related Products
  • ACQUITY UPLC Glycan BEH Amide 130Å, 1.7 μm, 2.1 x 50 mm (p/n 186004740)
  • ACQUITY UPLC Glycan BEH Amide 130Å, 1.7 μm, 2.1 x 150 mm (p/n 186004742)
  • XBridge Glycan BEH Amide XP, 130Å, 2.5 μm, 2.1 x 50 mm (p/n 186007263)
  • XBridge Glycan BEH Amide XP, 130Å, 2.5 μm, 2.1 x 150 mm (p/n 186007265)

GlycoWorks High-throughput Prep Kit [176003090]

The GlycoWorks High-throughput Sample Preparation Kit works synergistically with Waters ACQUITY UPLC Glycan Application Solution to generate high quality data from the analyses of pre-column derivatized, labeled N-glycans. A key component of this offering is Waters HILIC Solid-Phase Extraction (SPE) plate for separation of released glycans from the protein and for the subsequent separation of the labeled glycans from the free excess label. This kit can process 48 samples.

GlycoWorks Single Use Prep Kit [176003119]

The GlycoWorks Single Use Sample Preparation Kit was developed and rigorously tested to synergistically work with our existing ACQUITY UPLC Glycan Application Solution for the generation of high quality data from the analyses or pre-column derivatized, labeled N-glycans. A key component of this offering involves the use of Waters HILIC solid-phase extraction (SPE) material for the separation of released glycans from the protein and for the subsequent separation of the labeled glycans from the free excess label. This kit can process 10 samples.

RapiGest SF, 1 mg, 1/pk [186001860]

RapiGest SF, is a patented anionic surfactant that drastically improves in-gel and in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis to minimize high background noise often seen from other common surfactants. Add RapiGest SF to your proteolytic digestion, (using trypsin or other enzymes) to enhance digestion speed and increase peptide recovery. 

RapiGest SF, 1 mg , 5/pk [186001861]

RapiGest SF, is a patented anionic surfactant that drastically improves in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis by avoiding high background noise often seen from other common surfactants. Add RapiGest SF to your proteolytic digestion, (using trypsin or other enzymes) to enhance digestion speed and increase peptide recovery.

RapiGest SF, 50 mg, 1/pk [186002122]

RapiGest SF, is a patented anionic surfactant that drastically improves in-gel and in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis to minimize high background noise often seen from other common surfactants. Add RapiGest SF to your proteolytic digestion, (using trypsin or other enzymes) to enhance digestion speed and increase peptide recovery. 

RapiGest SF, 10 mg, 1/pk [186002123]

RapiGest SF, is a patented anionic surfactant that drastically improves in-gel and in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis to minimize high background noise often seen from other common surfactants. Add RapiGest SF to your proteolytic digestion, (using trypsin or other enzymes) to enhance digestion speed and increase peptide recovery. 

GlycoWorks HILIC 96-well Plate, 1/pk [186002780]

The GlycoWorks HILIC 96-well Plate is a key component of the GlycoWorks Sample Preparation offering. The HILIC solid-phase extraction (SPE) material is used and tested for the separation of released glycans from the protein and for the subsequent separation of the labeled glycans from the free excess label.

Intact mAb Mass Check Standard [186006552]

The Intact mAb Mass Check Standard is a LC-MS standard used as a qualitative tool for intact mass analysis. This standard is designed to be used for routine MS optimization, system setup and performance testing.

GlycoWorks Control Standard [186007033]

The GlycoWorks Control Standard is used for validation and troubleshooting when using the GlycoWorks High-throughput or Single Use kits. It is an undigested, unlabeled, Human IgG standard. When purchasing the GlycoWorks Single Use Sample Preparation Kit or the GlycoWorks High-throughput Sample Preparation Kit, this standard is included but can also be purchased separately.

GlycoWorks Reagent Kit [186007034]

The GlycoWorks Reagent Kit is provides reagents needed for both digestion and labeling reactions to follow the GlycoWorks High-throughput or Single Use Kit protocols. This kit is sold as a refill for use with the GlycoWorks Single Use Sample Preparation Kit or the GlycoWorks High-throughput Sample Preparation Kit. 

GlycoWorks HILIC 1 cc Catridge, 20/pk [186007080]

The GlycoWorks HILIC 1 cc Cartridge Pack is dual purpose; the catridges can be used for both the extraction of glycans as well as the removal of excess labeling reagent. Each pack contains 20, 1 cc cartridges for a total of 10 reactions for low sample volume environments following the GlycoWorks Single Use protocol.

GlycoWorks HILIC 1 cc Flangeless Catridge [186007239]

The GlycoWorks HILIC 1 cc Flangeless Cartridge Pack is dual purpose; the cartidges can be used for both the extraction of glycans as well as the removal of excess labeling reagent. The flangeless version is designed specifically for customers who use the positive pressure manifold (PPM).

GlycoWorks RapiFluor-MS N-Glycan Kit - 96 Samples [176003606]

The GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response.

GlycoWorks RapiFluor-MS N-Glycan Kit Starter Kit [176003635]

The GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response. Now you can use a single label that provides valuable information from characterization to routine monitoring. 

RapiFluor-MS Glycan Performance Test Standard [186007983]

The RapiFluor-MS Glycan Performance Test Standard is intended to be used as a benchmarking standard and labeled, complex control to compliment the GlycoWorks RapiFluor-MS N-Glycan Kit solution. 

GlycoWorks RapiFluor-MS N-Glycan Kit - 24 Samples [176003712]

Re-imagine a streamlined, fast, and highly sensitive way to analyze released N-glycans. With just 3 easy steps in 30 minutes, the GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response. Now you can use a single label that provides valuable information from characterization to routine monitoring. Glycan analysis just got easier and more sensitive.

RapiGest SF, 3 mg, 1/pk [186008090]

RapiGest SF, is a patented anionic surfactant that drastically improves in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis by avoiding high background noise often seen from other common surfactants.

GlycoWorks Rapid Deglycosylation Kit 3x8 [176003868]

GlycoWorks Rapid Deglycosylation Kit 1x24 [176003867]

GlycoWorks SPE Reagents [186007992]

GlycoWorks Rapid Buffer, 5 mL [186008100]

Glycoworks RapiFluor-MS N-Glycan Kit-24 sample [176003713]

Re-imagine a streamlined, fast, and highly sensitive way to analyze released N-glycans. With just 3 easy steps in 30 minutes, the GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response. Now you can use a single label that provides valuable information from characterization to routine monitoring. Glycan analysis just got easier and more sensitive.

Glycoworks RapiFluor-MS N-Glycan Refill Kit-24 sample [176003714]

Glycoworks Sample Collection Module [186007988]

GlycoWorks RapiFluor-MS N-Glycan Kit - 24 Samples [176003712]

Re-imagine a streamlined, fast, and highly sensitive way to analyze released N-glycans. With just 3 easy steps in 30 minutes, the GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response. Now you can use a single label that provides valuable information from characterization to routine monitoring. Glycan analysis just got easier and more sensitive.

Columns & Vials | Systems | Related Products
  • ACQUITY UPLC Glycan BEH Amide 130Å, 1.7 μm, 2.1 x 50 mm (p/n 186004740)
  • ACQUITY UPLC Glycan BEH Amide 130Å, 1.7 μm, 2.1 x 150 mm (p/n 186004742)
  • XBridge Glycan BEH Amide XP, 130Å, 2.5 μm, 2.1 x 50 mm (p/n 186007263)
  • XBridge Glycan BEH Amide XP, 130Å, 2.5 μm, 2.1 x 150 mm (p/n 186007265)

RapiGest SF, 10 mg, 1/pk [186002123]

RapiGest SF, is a patented anionic surfactant that drastically improves in-gel and in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis to minimize high background noise often seen from other common surfactants. Add RapiGest SF to your proteolytic digestion, (using trypsin or other enzymes) to enhance digestion speed and increase peptide recovery. 

Intact mAb Mass Check Standard [186006552]

The Intact mAb Mass Check Standard is a LC-MS standard used as a qualitative tool for intact mass analysis. This standard is designed to be used for routine MS optimization, system setup and performance testing.

GlycoWorks RapiFluor-MS N-Glycan Kit - 96 Samples [176003606]

The GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response.

GlycoWorks RapiFluor-MS N-Glycan Kit Starter Kit [176003635]

The GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response. Now you can use a single label that provides valuable information from characterization to routine monitoring. 

GlycoWorks RapiFluor-MS N-Glycan Kit - 96 Samples [176003606]

The GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response.

Columns & Vials | Systems | Related Products

 

RapiGest SF, 10 mg, 1/pk [186002123]

RapiGest SF, is a patented anionic surfactant that drastically improves in-gel and in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis to minimize high background noise often seen from other common surfactants. Add RapiGest SF to your proteolytic digestion, (using trypsin or other enzymes) to enhance digestion speed and increase peptide recovery. 

Intact mAb Mass Check Standard [186006552]

The Intact mAb Mass Check Standard is a LC-MS standard used as a qualitative tool for intact mass analysis. This standard is designed to be used for routine MS optimization, system setup and performance testing.

Ammonium Formate Concentrate-Glycan Analysis [186007081]

The Ammonium Formate Concentrate is the recommended buffer that is used with the Biopharm/Glycan system, using the  ACQUITY UPLC® H-class and the ACQUITY UPLC BEH Glycan Column.

GlycoWorks RapiFluor-MS N-Glycan Kit Starter Kit [176003635]

The GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response. Now you can use a single label that provides valuable information from characterization to routine monitoring. 

Columns & Vials | Systems | Related Products
  • ACQUITY UPLC Glycan BEH Amide 130Å, 1.7 μm, 2.1 x 50 mm (p/n 186004740)
  • ACQUITY UPLC Glycan BEH Amide 130Å, 1.7 μm, 2.1 x 150 mm (p/n 186004742)
  • XBridge Glycan BEH Amide XP, 130Å, 2.5 μm, 2.1 x 50 mm (p/n 186007263)
  • XBridge Glycan BEH Amide XP, 130Å, 2.5 μm, 2.1 x 150 mm (p/n 186007265)

RapiGest SF, 10 mg, 1/pk [186002123]

RapiGest SF, is a patented anionic surfactant that drastically improves in-gel and in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis to minimize high background noise often seen from other common surfactants. Add RapiGest SF to your proteolytic digestion, (using trypsin or other enzymes) to enhance digestion speed and increase peptide recovery. 

Intact mAb Mass Check Standard [186006552]

The Intact mAb Mass Check Standard is a LC-MS standard used as a qualitative tool for intact mass analysis. This standard is designed to be used for routine MS optimization, system setup and performance testing.

Ammonium Formate Concentrate-Glycan Analysis [186007081]

The Ammonium Formate Concentrate is the recommended buffer that is used with the Biopharm/Glycan system, using the  ACQUITY UPLC® H-class and the ACQUITY UPLC BEH Glycan Column.

Glycoworks RapiFluor-MS N-Glycan Kit-24 sample [176003713]

Re-imagine a streamlined, fast, and highly sensitive way to analyze released N-glycans. With just 3 easy steps in 30 minutes, the GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response. Now you can use a single label that provides valuable information from characterization to routine monitoring. Glycan analysis just got easier and more sensitive.

Columns & Vials | Systems | Related Products
  • ACQUITY UPLC Glycan BEH Amide 130Å, 1.7 μm, 2.1 x 50 mm (p/n 186004740)
  • ACQUITY UPLC Glycan BEH Amide 130Å, 1.7 μm, 2.1 x 150 mm (p/n 186004742)
  • XBridge Glycan BEH Amide XP, 130Å, 2.5 μm, 2.1 x 50 mm (p/n 186007263)
  • XBridge Glycan BEH Amide XP, 130Å, 2.5 μm, 2.1 x 150 mm (p/n 186007265)

GlycoWorks High-throughput Prep Kit [176003090]

The GlycoWorks High-throughput Sample Preparation Kit works synergistically with Waters ACQUITY UPLC Glycan Application Solution to generate high quality data from the analyses of pre-column derivatized, labeled N-glycans. A key component of this offering is Waters HILIC Solid-Phase Extraction (SPE) plate for separation of released glycans from the protein and for the subsequent separation of the labeled glycans from the free excess label. This kit can process 48 samples.

GlycoWorks Single Use Prep Kit [176003119]

The GlycoWorks Single Use Sample Preparation Kit was developed and rigorously tested to synergistically work with our existing ACQUITY UPLC Glycan Application Solution for the generation of high quality data from the analyses or pre-column derivatized, labeled N-glycans. A key component of this offering involves the use of Waters HILIC solid-phase extraction (SPE) material for the separation of released glycans from the protein and for the subsequent separation of the labeled glycans from the free excess label. This kit can process 10 samples.

RapiGest SF, 1 mg, 1/pk [186001860]

RapiGest SF, is a patented anionic surfactant that drastically improves in-gel and in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis to minimize high background noise often seen from other common surfactants. Add RapiGest SF to your proteolytic digestion, (using trypsin or other enzymes) to enhance digestion speed and increase peptide recovery. 

RapiGest SF, 1 mg , 5/pk [186001861]

RapiGest SF, is a patented anionic surfactant that drastically improves in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis by avoiding high background noise often seen from other common surfactants. Add RapiGest SF to your proteolytic digestion, (using trypsin or other enzymes) to enhance digestion speed and increase peptide recovery.

RapiGest SF, 50 mg, 1/pk [186002122]

RapiGest SF, is a patented anionic surfactant that drastically improves in-gel and in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis to minimize high background noise often seen from other common surfactants. Add RapiGest SF to your proteolytic digestion, (using trypsin or other enzymes) to enhance digestion speed and increase peptide recovery. 

RapiGest SF, 10 mg, 1/pk [186002123]

RapiGest SF, is a patented anionic surfactant that drastically improves in-gel and in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis to minimize high background noise often seen from other common surfactants. Add RapiGest SF to your proteolytic digestion, (using trypsin or other enzymes) to enhance digestion speed and increase peptide recovery. 

GlycoWorks HILIC 96-well Plate, 1/pk [186002780]

The GlycoWorks HILIC 96-well Plate is a key component of the GlycoWorks Sample Preparation offering. The HILIC solid-phase extraction (SPE) material is used and tested for the separation of released glycans from the protein and for the subsequent separation of the labeled glycans from the free excess label.

GlycoWorks Control Standard [186007033]

The GlycoWorks Control Standard is used for validation and troubleshooting when using the GlycoWorks High-throughput or Single Use kits. It is an undigested, unlabeled, Human IgG standard. When purchasing the GlycoWorks Single Use Sample Preparation Kit or the GlycoWorks High-throughput Sample Preparation Kit, this standard is included but can also be purchased separately.

GlycoWorks Reagent Kit [186007034]

The GlycoWorks Reagent Kit is provides reagents needed for both digestion and labeling reactions to follow the GlycoWorks High-throughput or Single Use Kit protocols. This kit is sold as a refill for use with the GlycoWorks Single Use Sample Preparation Kit or the GlycoWorks High-throughput Sample Preparation Kit. 

GlycoWorks HILIC 1 cc Catridge, 20/pk [186007080]

The GlycoWorks HILIC 1 cc Cartridge Pack is dual purpose; the catridges can be used for both the extraction of glycans as well as the removal of excess labeling reagent. Each pack contains 20, 1 cc cartridges for a total of 10 reactions for low sample volume environments following the GlycoWorks Single Use protocol.

GlycoWorks HILIC 1 cc Flangeless Catridge [186007239]

The GlycoWorks HILIC 1 cc Flangeless Cartridge Pack is dual purpose; the cartidges can be used for both the extraction of glycans as well as the removal of excess labeling reagent. The flangeless version is designed specifically for customers who use the positive pressure manifold (PPM).

GlycoWorks RapiFluor-MS N-Glycan Kit - 96 Samples [176003606]

The GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response.

GlycoWorks RapiFluor-MS N-Glycan Kit Starter Kit [176003635]

The GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response. Now you can use a single label that provides valuable information from characterization to routine monitoring. 

RapiFluor-MS Glycan Performance Test Standard [186007983]

The RapiFluor-MS Glycan Performance Test Standard is intended to be used as a benchmarking standard and labeled, complex control to compliment the GlycoWorks RapiFluor-MS N-Glycan Kit solution. 

RapiFluor-MS Dextran Calibration Ladder [186007982]

The RapiFluor-MS Dextran Calibration Ladder was developed to help take full advantage of the BEH glycan column, to assist glycan profiling. The glycan profile obtained from UPLC-HILIC/FLR systems can be calibrated against the RapiFluor-MS-labeled dextran ladder and assigned with glucose unit (GU) values. 

GlycoWorks RapiFluor-MS N-Glycan Kit - 24 Samples [176003712]

Re-imagine a streamlined, fast, and highly sensitive way to analyze released N-glycans. With just 3 easy steps in 30 minutes, the GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response. Now you can use a single label that provides valuable information from characterization to routine monitoring. Glycan analysis just got easier and more sensitive.

RapiGest SF, 3 mg, 1/pk [186008090]

RapiGest SF, is a patented anionic surfactant that drastically improves in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis by avoiding high background noise often seen from other common surfactants.

GlycoWorks Rapid Deglycosylation Kit 3x8 [176003868]

GlycoWorks Rapid Deglycosylation Kit 1x24 [176003867]

GlycoWorks SPE Reagents [186007992]

GlycoWorks Rapid Buffer, 5 mL [186008100]

GlycoWorks High-throughput Prep Kit [176003090]

The GlycoWorks High-throughput Sample Preparation Kit works synergistically with Waters ACQUITY UPLC Glycan Application Solution to generate high quality data from the analyses of pre-column derivatized, labeled N-glycans. A key component of this offering is Waters HILIC Solid-Phase Extraction (SPE) plate for separation of released glycans from the protein and for the subsequent separation of the labeled glycans from the free excess label. This kit can process 48 samples.

GlycoWorks Single Use Prep Kit [176003119]

The GlycoWorks Single Use Sample Preparation Kit was developed and rigorously tested to synergistically work with our existing ACQUITY UPLC Glycan Application Solution for the generation of high quality data from the analyses or pre-column derivatized, labeled N-glycans. A key component of this offering involves the use of Waters HILIC solid-phase extraction (SPE) material for the separation of released glycans from the protein and for the subsequent separation of the labeled glycans from the free excess label. This kit can process 10 samples.

RapiGest SF, 1 mg, 1/pk [186001860]

RapiGest SF, is a patented anionic surfactant that drastically improves in-gel and in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis to minimize high background noise often seen from other common surfactants. Add RapiGest SF to your proteolytic digestion, (using trypsin or other enzymes) to enhance digestion speed and increase peptide recovery. 

RapiGest SF, 1 mg , 5/pk [186001861]

RapiGest SF, is a patented anionic surfactant that drastically improves in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis by avoiding high background noise often seen from other common surfactants. Add RapiGest SF to your proteolytic digestion, (using trypsin or other enzymes) to enhance digestion speed and increase peptide recovery.

RapiGest SF, 50 mg, 1/pk [186002122]

RapiGest SF, is a patented anionic surfactant that drastically improves in-gel and in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis to minimize high background noise often seen from other common surfactants. Add RapiGest SF to your proteolytic digestion, (using trypsin or other enzymes) to enhance digestion speed and increase peptide recovery. 

RapiGest SF, 10 mg, 1/pk [186002123]

RapiGest SF, is a patented anionic surfactant that drastically improves in-gel and in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis to minimize high background noise often seen from other common surfactants. Add RapiGest SF to your proteolytic digestion, (using trypsin or other enzymes) to enhance digestion speed and increase peptide recovery. 

GlycoWorks HILIC 96-well Plate, 1/pk [186002780]

The GlycoWorks HILIC 96-well Plate is a key component of the GlycoWorks Sample Preparation offering. The HILIC solid-phase extraction (SPE) material is used and tested for the separation of released glycans from the protein and for the subsequent separation of the labeled glycans from the free excess label.

GlycoWorks Control Standard [186007033]

The GlycoWorks Control Standard is used for validation and troubleshooting when using the GlycoWorks High-throughput or Single Use kits. It is an undigested, unlabeled, Human IgG standard. When purchasing the GlycoWorks Single Use Sample Preparation Kit or the GlycoWorks High-throughput Sample Preparation Kit, this standard is included but can also be purchased separately.

GlycoWorks Reagent Kit [186007034]

The GlycoWorks Reagent Kit is provides reagents needed for both digestion and labeling reactions to follow the GlycoWorks High-throughput or Single Use Kit protocols. This kit is sold as a refill for use with the GlycoWorks Single Use Sample Preparation Kit or the GlycoWorks High-throughput Sample Preparation Kit. 

GlycoWorks HILIC 1 cc Catridge, 20/pk [186007080]

The GlycoWorks HILIC 1 cc Cartridge Pack is dual purpose; the catridges can be used for both the extraction of glycans as well as the removal of excess labeling reagent. Each pack contains 20, 1 cc cartridges for a total of 10 reactions for low sample volume environments following the GlycoWorks Single Use protocol.

GlycoWorks HILIC 1 cc Flangeless Catridge [186007239]

The GlycoWorks HILIC 1 cc Flangeless Cartridge Pack is dual purpose; the cartidges can be used for both the extraction of glycans as well as the removal of excess labeling reagent. The flangeless version is designed specifically for customers who use the positive pressure manifold (PPM).

GlycoWorks RapiFluor-MS N-Glycan Kit - 96 Samples [176003606]

The GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response.

GlycoWorks RapiFluor-MS N-Glycan Kit Starter Kit [176003635]

The GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response. Now you can use a single label that provides valuable information from characterization to routine monitoring. 

RapiFluor-MS Glycan Performance Test Standard [186007983]

The RapiFluor-MS Glycan Performance Test Standard is intended to be used as a benchmarking standard and labeled, complex control to compliment the GlycoWorks RapiFluor-MS N-Glycan Kit solution. 

RapiFluor-MS Dextran Calibration Ladder [186007982]

The RapiFluor-MS Dextran Calibration Ladder was developed to help take full advantage of the BEH glycan column, to assist glycan profiling. The glycan profile obtained from UPLC-HILIC/FLR systems can be calibrated against the RapiFluor-MS-labeled dextran ladder and assigned with glucose unit (GU) values. 

GlycoWorks RapiFluor-MS N-Glycan Kit - 24 Samples [176003712]

Re-imagine a streamlined, fast, and highly sensitive way to analyze released N-glycans. With just 3 easy steps in 30 minutes, the GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response. Now you can use a single label that provides valuable information from characterization to routine monitoring. Glycan analysis just got easier and more sensitive.

RapiGest SF, 3 mg, 1/pk [186008090]

RapiGest SF, is a patented anionic surfactant that drastically improves in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis by avoiding high background noise often seen from other common surfactants.

GlycoWorks Rapid Deglycosylation Kit 3x8 [176003868]

GlycoWorks Rapid Deglycosylation Kit 1x24 [176003867]

GlycoWorks SPE Reagents [186007992]

GlycoWorks Rapid Buffer, 5 mL [186008100]

Glycoworks RapiFluor-MS N-Glycan Kit-24 sample [176003713]

Re-imagine a streamlined, fast, and highly sensitive way to analyze released N-glycans. With just 3 easy steps in 30 minutes, the GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response. Now you can use a single label that provides valuable information from characterization to routine monitoring. Glycan analysis just got easier and more sensitive.

GlycoWorks Reagent Kit [186007034]

The GlycoWorks Reagent Kit is provides reagents needed for both digestion and labeling reactions to follow the GlycoWorks High-throughput or Single Use Kit protocols. This kit is sold as a refill for use with the GlycoWorks Single Use Sample Preparation Kit or the GlycoWorks High-throughput Sample Preparation Kit. 

Columns & Vials | Related Products
  • ACQUITY UPLC Glycan BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pk (186004741)
  • XBridge Glycan BEH Amide Column, 130Å, 3.5 µm, 2.1 mm X 100 mm, 1/pk (186007503)

GlycoWorks High-throughput Prep Kit [176003090]

The GlycoWorks High-throughput Sample Preparation Kit works synergistically with Waters ACQUITY UPLC Glycan Application Solution to generate high quality data from the analyses of pre-column derivatized, labeled N-glycans. A key component of this offering is Waters HILIC Solid-Phase Extraction (SPE) plate for separation of released glycans from the protein and for the subsequent separation of the labeled glycans from the free excess label. This kit can process 48 samples.

GlycoWorks Single Use Prep Kit [176003119]

The GlycoWorks Single Use Sample Preparation Kit was developed and rigorously tested to synergistically work with our existing ACQUITY UPLC Glycan Application Solution for the generation of high quality data from the analyses or pre-column derivatized, labeled N-glycans. A key component of this offering involves the use of Waters HILIC solid-phase extraction (SPE) material for the separation of released glycans from the protein and for the subsequent separation of the labeled glycans from the free excess label. This kit can process 10 samples.

RapiGest SF, 1 mg, 1/pk [186001860]

RapiGest SF, is a patented anionic surfactant that drastically improves in-gel and in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis to minimize high background noise often seen from other common surfactants. Add RapiGest SF to your proteolytic digestion, (using trypsin or other enzymes) to enhance digestion speed and increase peptide recovery. 

GlycoWorks High-throughput Prep Kit [176003090]

The GlycoWorks High-throughput Sample Preparation Kit works synergistically with Waters ACQUITY UPLC Glycan Application Solution to generate high quality data from the analyses of pre-column derivatized, labeled N-glycans. A key component of this offering is Waters HILIC Solid-Phase Extraction (SPE) plate for separation of released glycans from the protein and for the subsequent separation of the labeled glycans from the free excess label. This kit can process 48 samples.

GlycoWorks Single Use Prep Kit [176003119]

The GlycoWorks Single Use Sample Preparation Kit was developed and rigorously tested to synergistically work with our existing ACQUITY UPLC Glycan Application Solution for the generation of high quality data from the analyses or pre-column derivatized, labeled N-glycans. A key component of this offering involves the use of Waters HILIC solid-phase extraction (SPE) material for the separation of released glycans from the protein and for the subsequent separation of the labeled glycans from the free excess label. This kit can process 10 samples.

RapiGest SF, 1 mg, 1/pk [186001860]

RapiGest SF, is a patented anionic surfactant that drastically improves in-gel and in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis to minimize high background noise often seen from other common surfactants. Add RapiGest SF to your proteolytic digestion, (using trypsin or other enzymes) to enhance digestion speed and increase peptide recovery. 

RapiGest SF, 1 mg , 5/pk [186001861]

RapiGest SF, is a patented anionic surfactant that drastically improves in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis by avoiding high background noise often seen from other common surfactants. Add RapiGest SF to your proteolytic digestion, (using trypsin or other enzymes) to enhance digestion speed and increase peptide recovery.

RapiGest SF, 50 mg, 1/pk [186002122]

RapiGest SF, is a patented anionic surfactant that drastically improves in-gel and in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis to minimize high background noise often seen from other common surfactants. Add RapiGest SF to your proteolytic digestion, (using trypsin or other enzymes) to enhance digestion speed and increase peptide recovery. 

RapiGest SF, 10 mg, 1/pk [186002123]

RapiGest SF, is a patented anionic surfactant that drastically improves in-gel and in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis to minimize high background noise often seen from other common surfactants. Add RapiGest SF to your proteolytic digestion, (using trypsin or other enzymes) to enhance digestion speed and increase peptide recovery. 

GlycoWorks HILIC 96-well Plate, 1/pk [186002780]

The GlycoWorks HILIC 96-well Plate is a key component of the GlycoWorks Sample Preparation offering. The HILIC solid-phase extraction (SPE) material is used and tested for the separation of released glycans from the protein and for the subsequent separation of the labeled glycans from the free excess label.

GlycoWorks Control Standard [186007033]

The GlycoWorks Control Standard is used for validation and troubleshooting when using the GlycoWorks High-throughput or Single Use kits. It is an undigested, unlabeled, Human IgG standard. When purchasing the GlycoWorks Single Use Sample Preparation Kit or the GlycoWorks High-throughput Sample Preparation Kit, this standard is included but can also be purchased separately.

GlycoWorks Reagent Kit [186007034]

The GlycoWorks Reagent Kit is provides reagents needed for both digestion and labeling reactions to follow the GlycoWorks High-throughput or Single Use Kit protocols. This kit is sold as a refill for use with the GlycoWorks Single Use Sample Preparation Kit or the GlycoWorks High-throughput Sample Preparation Kit. 

GlycoWorks HILIC 1 cc Catridge, 20/pk [186007080]

The GlycoWorks HILIC 1 cc Cartridge Pack is dual purpose; the catridges can be used for both the extraction of glycans as well as the removal of excess labeling reagent. Each pack contains 20, 1 cc cartridges for a total of 10 reactions for low sample volume environments following the GlycoWorks Single Use protocol.

GlycoWorks HILIC 1 cc Flangeless Catridge [186007239]

The GlycoWorks HILIC 1 cc Flangeless Cartridge Pack is dual purpose; the cartidges can be used for both the extraction of glycans as well as the removal of excess labeling reagent. The flangeless version is designed specifically for customers who use the positive pressure manifold (PPM).

GlycoWorks RapiFluor-MS N-Glycan Kit - 96 Samples [176003606]

The GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response.

GlycoWorks RapiFluor-MS N-Glycan Kit Starter Kit [176003635]

The GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response. Now you can use a single label that provides valuable information from characterization to routine monitoring. 

RapiFluor-MS Glycan Performance Test Standard [186007983]

The RapiFluor-MS Glycan Performance Test Standard is intended to be used as a benchmarking standard and labeled, complex control to compliment the GlycoWorks RapiFluor-MS N-Glycan Kit solution. 

RapiFluor-MS Dextran Calibration Ladder [186007982]

The RapiFluor-MS Dextran Calibration Ladder was developed to help take full advantage of the BEH glycan column, to assist glycan profiling. The glycan profile obtained from UPLC-HILIC/FLR systems can be calibrated against the RapiFluor-MS-labeled dextran ladder and assigned with glucose unit (GU) values. 

GlycoWorks RapiFluor-MS N-Glycan Kit - 24 Samples [176003712]

Re-imagine a streamlined, fast, and highly sensitive way to analyze released N-glycans. With just 3 easy steps in 30 minutes, the GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response. Now you can use a single label that provides valuable information from characterization to routine monitoring. Glycan analysis just got easier and more sensitive.

RapiGest SF, 3 mg, 1/pk [186008090]

RapiGest SF, is a patented anionic surfactant that drastically improves in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis by avoiding high background noise often seen from other common surfactants.

GlycoWorks Rapid Deglycosylation Kit 3x8 [176003868]

GlycoWorks Rapid Deglycosylation Kit 1x24 [176003867]

GlycoWorks SPE Reagents [186007992]

GlycoWorks Rapid Buffer, 5 mL [186008100]

Glycoworks RapiFluor-MS N-Glycan Kit-24 sample [176003713]

Re-imagine a streamlined, fast, and highly sensitive way to analyze released N-glycans. With just 3 easy steps in 30 minutes, the GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response. Now you can use a single label that provides valuable information from characterization to routine monitoring. Glycan analysis just got easier and more sensitive.

Glycoworks RapiFluor-MS N-Glycan Refill Kit-24 sample [176003714]

GlycoWorks Single Use Prep Kit [176003119]

The GlycoWorks Single Use Sample Preparation Kit was developed and rigorously tested to synergistically work with our existing ACQUITY UPLC Glycan Application Solution for the generation of high quality data from the analyses or pre-column derivatized, labeled N-glycans. A key component of this offering involves the use of Waters HILIC solid-phase extraction (SPE) material for the separation of released glycans from the protein and for the subsequent separation of the labeled glycans from the free excess label. This kit can process 10 samples.

Columns & Vials | Related Products
  • ACQUITY UPLC Glycan BEH Amide Column, 130Å, 1.7 µm, 2.1 mm X 100 mm, 1/pk (186004741)
  • XBridge Glycan BEH Amide Column, 130Å, 3.5 µm, 2.1 mm X 100 mm, 1/pk (186007503)
  • TruView LCMS Certified Vials (186005666CV)

GlycoWorks High-throughput Prep Kit [176003090]

The GlycoWorks High-throughput Sample Preparation Kit works synergistically with Waters ACQUITY UPLC Glycan Application Solution to generate high quality data from the analyses of pre-column derivatized, labeled N-glycans. A key component of this offering is Waters HILIC Solid-Phase Extraction (SPE) plate for separation of released glycans from the protein and for the subsequent separation of the labeled glycans from the free excess label. This kit can process 48 samples.

GlycoWorks HILIC 1 cc Catridge, 20/pk [186007080]

The GlycoWorks HILIC 1 cc Cartridge Pack is dual purpose; the catridges can be used for both the extraction of glycans as well as the removal of excess labeling reagent. Each pack contains 20, 1 cc cartridges for a total of 10 reactions for low sample volume environments following the GlycoWorks Single Use protocol.

LC-MS

GlycoWorks High-throughput Prep Kit [176003090]

The GlycoWorks High-throughput Sample Preparation Kit works synergistically with Waters ACQUITY UPLC Glycan Application Solution to generate high quality data from the analyses of pre-column derivatized, labeled N-glycans. A key component of this offering is Waters HILIC Solid-Phase Extraction (SPE) plate for separation of released glycans from the protein and for the subsequent separation of the labeled glycans from the free excess label. This kit can process 48 samples.

GlycoWorks Single Use Prep Kit [176003119]

The GlycoWorks Single Use Sample Preparation Kit was developed and rigorously tested to synergistically work with our existing ACQUITY UPLC Glycan Application Solution for the generation of high quality data from the analyses or pre-column derivatized, labeled N-glycans. A key component of this offering involves the use of Waters HILIC solid-phase extraction (SPE) material for the separation of released glycans from the protein and for the subsequent separation of the labeled glycans from the free excess label. This kit can process 10 samples.

RapiGest SF, 1 mg, 1/pk [186001860]

RapiGest SF, is a patented anionic surfactant that drastically improves in-gel and in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis to minimize high background noise often seen from other common surfactants. Add RapiGest SF to your proteolytic digestion, (using trypsin or other enzymes) to enhance digestion speed and increase peptide recovery. 

RapiGest SF, 1 mg , 5/pk [186001861]

RapiGest SF, is a patented anionic surfactant that drastically improves in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis by avoiding high background noise often seen from other common surfactants. Add RapiGest SF to your proteolytic digestion, (using trypsin or other enzymes) to enhance digestion speed and increase peptide recovery.

RapiGest SF, 50 mg, 1/pk [186002122]

RapiGest SF, is a patented anionic surfactant that drastically improves in-gel and in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis to minimize high background noise often seen from other common surfactants. Add RapiGest SF to your proteolytic digestion, (using trypsin or other enzymes) to enhance digestion speed and increase peptide recovery. 

RapiGest SF, 10 mg, 1/pk [186002123]

RapiGest SF, is a patented anionic surfactant that drastically improves in-gel and in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis to minimize high background noise often seen from other common surfactants. Add RapiGest SF to your proteolytic digestion, (using trypsin or other enzymes) to enhance digestion speed and increase peptide recovery. 

GlycoWorks HILIC 96-well Plate, 1/pk [186002780]

The GlycoWorks HILIC 96-well Plate is a key component of the GlycoWorks Sample Preparation offering. The HILIC solid-phase extraction (SPE) material is used and tested for the separation of released glycans from the protein and for the subsequent separation of the labeled glycans from the free excess label.

GlycoWorks Control Standard [186007033]

The GlycoWorks Control Standard is used for validation and troubleshooting when using the GlycoWorks High-throughput or Single Use kits. It is an undigested, unlabeled, Human IgG standard. When purchasing the GlycoWorks Single Use Sample Preparation Kit or the GlycoWorks High-throughput Sample Preparation Kit, this standard is included but can also be purchased separately.

GlycoWorks Reagent Kit [186007034]

The GlycoWorks Reagent Kit is provides reagents needed for both digestion and labeling reactions to follow the GlycoWorks High-throughput or Single Use Kit protocols. This kit is sold as a refill for use with the GlycoWorks Single Use Sample Preparation Kit or the GlycoWorks High-throughput Sample Preparation Kit. 

GlycoWorks HILIC 1 cc Catridge, 20/pk [186007080]

The GlycoWorks HILIC 1 cc Cartridge Pack is dual purpose; the catridges can be used for both the extraction of glycans as well as the removal of excess labeling reagent. Each pack contains 20, 1 cc cartridges for a total of 10 reactions for low sample volume environments following the GlycoWorks Single Use protocol.

GlycoWorks HILIC 1 cc Flangeless Catridge [186007239]

The GlycoWorks HILIC 1 cc Flangeless Cartridge Pack is dual purpose; the cartidges can be used for both the extraction of glycans as well as the removal of excess labeling reagent. The flangeless version is designed specifically for customers who use the positive pressure manifold (PPM).

GlycoWorks RapiFluor-MS N-Glycan Kit - 96 Samples [176003606]

The GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response.

GlycoWorks RapiFluor-MS N-Glycan Kit Starter Kit [176003635]

The GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response. Now you can use a single label that provides valuable information from characterization to routine monitoring. 

RapiFluor-MS Glycan Performance Test Standard [186007983]

The RapiFluor-MS Glycan Performance Test Standard is intended to be used as a benchmarking standard and labeled, complex control to compliment the GlycoWorks RapiFluor-MS N-Glycan Kit solution. 

RapiFluor-MS Dextran Calibration Ladder [186007982]

The RapiFluor-MS Dextran Calibration Ladder was developed to help take full advantage of the BEH glycan column, to assist glycan profiling. The glycan profile obtained from UPLC-HILIC/FLR systems can be calibrated against the RapiFluor-MS-labeled dextran ladder and assigned with glucose unit (GU) values. 

GlycoWorks RapiFluor-MS N-Glycan Kit - 24 Samples [176003712]

Re-imagine a streamlined, fast, and highly sensitive way to analyze released N-glycans. With just 3 easy steps in 30 minutes, the GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response. Now you can use a single label that provides valuable information from characterization to routine monitoring. Glycan analysis just got easier and more sensitive.

RapiGest SF, 3 mg, 1/pk [186008090]

RapiGest SF, is a patented anionic surfactant that drastically improves in-solution protein digestion in terms of speed and peptide recovery. It is especially valuable in protein sample preparation for mass spectrometry (MS) analysis by avoiding high background noise often seen from other common surfactants.

GlycoWorks Rapid Deglycosylation Kit 3x8 [176003868]

GlycoWorks Rapid Deglycosylation Kit 1x24 [176003867]

Modular Heat Block for 1 ml Tubes [186007985]

The modular heat block is customized to hold 1 ml tubes that are in strips of 8 in a 96 well format.  This is specifically used in the GlycoWorks RapiFluor-MS N-Glycan Kit workflow using the tubes included in the Sample Collection Module. The heat block has been tested to fit into the following dry bath heaters. 

Related Products

GlycoWorks RapiFluor-MS N-Glycan Kit - 96 Samples [176003606]

The GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response.

GlycoWorks RapiFluor-MS N-Glycan Kit Starter Kit [176003635]

The GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response. Now you can use a single label that provides valuable information from characterization to routine monitoring. 

GlycoWorks RapiFluor-MS N-Glycan Kit - 24 Samples [176003712]

Re-imagine a streamlined, fast, and highly sensitive way to analyze released N-glycans. With just 3 easy steps in 30 minutes, the GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response. Now you can use a single label that provides valuable information from characterization to routine monitoring. Glycan analysis just got easier and more sensitive.

RapiFluor-MS Dextran Calibration Ladder [186007982]

The RapiFluor-MS Dextran Calibration Ladder was developed to help take full advantage of the BEH glycan column, to assist glycan profiling. The glycan profile obtained from UPLC-HILIC/FLR systems can be calibrated against the RapiFluor-MS-labeled dextran ladder and assigned with glucose unit (GU) values. 

Columns & Vials | Systems | Related Products
  • ACQUITY UPLC Glycan BEH Amide 130Å, 1.7 μm, 2.1 x 50 mm (p/n 186004740)
  • ACQUITY UPLC Glycan BEH Amide 130Å, 1.7 μm, 2.1 x 150 mm (p/n 186004742)
  • XBridge Glycan BEH Amide XP, 130Å, 2.5 μm, 2.1 x 50 mm (p/n 186007263)
  • XBridge Glycan BEH Amide XP, 130Å, 2.5 μm, 2.1 x 150 mm (p/n 186007265)

GlycoWorks RapiFluor-MS N-Glycan Kit - 96 Samples [176003606]

The GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response.

GlycoWorks RapiFluor-MS N-Glycan Kit Starter Kit [176003635]

The GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response. Now you can use a single label that provides valuable information from characterization to routine monitoring. 

RapiFluor-MS Glycan Performance Test Standard [186007983]

The RapiFluor-MS Glycan Performance Test Standard is intended to be used as a benchmarking standard and labeled, complex control to compliment the GlycoWorks RapiFluor-MS N-Glycan Kit solution. 

Columns & Vials | Systems | Related Products
  • ACQUITY UPLC Glycan BEH Amide 130Å, 1.7 μm, 2.1 x 50 mm (p/n 186004740)
  • ACQUITY UPLC Glycan BEH Amide 130Å, 1.7 μm, 2.1 x 150 mm (p/n 186004742)
  • XBridge Glycan BEH Amide XP, 130Å, 2.5 μm, 2.1 x 50 mm (p/n 186007263)
  • XBridge Glycan BEH Amide XP, 130Å, 2.5 μm, 2.1 x 150 mm (p/n 186007265)

GlycoWorks RapiFluor-MS N-Glycan Kit - 96 Samples [176003606]

The GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response.

GlycoWorks RapiFluor-MS N-Glycan Kit Starter Kit [176003635]

The GlycoWorks RapiFluor-MS N-Glycan Kit reduces complicated, time-consuming sample preparation. RapiFluor-MS’s unique chemical attributes provide increased fluorescence quantification and supreme mass spectral response. Now you can use a single label that provides valuable information from characterization to routine monitoring. 

34 Maple Street Milford, MA USA
T: 508-478-2000
F: 508-872-1990
Sales Offices

© 2017 Waters Corporation
Terms and Conditions | Privacy Policy