- Advanced Polymer Chromatography (APC)
- UPLC with UV Detection
- GC
- GC-MS
- HPLC with RI, ELSD, Electrochemical, Fluorescence or Conductivity Detection
- HPLC or Prep Systems with UV Detection
- SFC and Convergence Chromatography (UPC2)
- Single Quadrupole Mass Detection
- Tandem Quadrupole (Triple Quadrupole )
- Time-of-flight Mass Spectrometry
- Amino Acids
- Cations
- Gel Filtration
- Gel Permeation
- Glycans
- Ion Calibration
- Oligonucleotides
- Peptides
- Pesticides
- Proteins
- QC Trace Metals
- Small Molecules
- Total Chlorine
- pH Buffers
- Quality Control (QC) Reference Material
- Reagents
- System Performance Standards and Reagents
Find Your Results

.jpg)
From QC testing of final product to meeting the demand for new products with additional nutritional value, food and beverage manufacturers face difficult challenges. Waters can help meet those challenges with standards and reagents that offer the sensitivity, reproducibility, and versatility required to ensure you can profitably manage laboratory requirements. At Waters, we have made a unique commitment to the food industry, and we are ready to partner with you to improve and optimize your analysis capabilities.
- Test complex food and beverage samples consistently and routinely
- Improve confidence in results and instrumentation
- Take advantage of Waters' unique commitment and experience in the food industry
20 Pesticide Mix Standard [186006348]
The 20 Pesticide Standard Mix is intended for use with the Waters Pesticide Screening Application Solution with UNIFI. This application prepares laboratories to test more food and environmental samples for increasing numbers of residues and contaminants not just at, but below, regulatory limits. The Waters Pesticide Screening Application Solution is custom-built to minimize both false-positive (non-compliant) and false negative (compliant) findings. Now, for the first time, scientists will be able to reliably report the presence or absence of pesticide residues, easily streamline workflows, and increase the speed of analysis of complex matrices.

350 mg/L Phosphate Calibration Standard [186008047]
The 350 mg/L Phosphate Calibration Standard is a component of the IC Phosphate Calibration Kit (350-550 mg/L), which is intended for use as a calibration standard for ion chromatography to analyze phosphate/phosphoric acid levels in beverages.
.jpg)
445 mg/L Phosphate Check Standard [186008051]
The 445 mg/L Phosphate Check Standard is a component of the IC Phosphate Calibration Kit (350-550 mg/L). This standard is intended for use as a check standard for ion chromatography to analyze phosphate/phosphoric acid levels in beverages.
.jpg)
450 mg/L Phosphate Calibration Standard [186008048]
The 450 mg/L Phosphate Calibration Standard is a component of the IC Phosphate Calibration Kit (350-550 mg/L), which is intended for use as a calibration standard for ion chromatography to analyze phosphate/phosphoric acid levels in beverages.
.jpg)
550 mg/L Phosphate Calibration Standard [186008049]
The 550 mg/L Phosphate Calibration Standard is a component of the IC Phosphate Calibration Kit (350-550 mg/L), which is intended for use as a calibration standard for ion chromatography to analyze phosphate/phosphoric acid levels in beverages
.jpg)
650 mg/L Phosphate Calibration Standard [186008050]
The 650 mg/L Phosphate Calibration Standard is a component of the IC Phosphate Calibration Kit (350-550 mg/L), which is intended for use as a calibration standard for ion chromatography to analyze phosphate/phosphoric acid levels in beverages.
.jpg)
AccQ-Fluor Reagent Kit [WAT052880]
The AccQ•Fluor Reagent Kit is used for derivatization of primary and secondary amino acids in a single step prior to HPLC analysis. The product is sufficient for 250 analyses.
.jpg)
AccQ•Tag Chemistry Kit (250 Analyses) [WAT052875]
The AccQ•Tag Chemistry Kit contains the necessary components needed for HPLC analysis of protein and peptide hydrolysate amino acids. The kit provides sufficient reagents for 250 analyses.
.jpg)
AccQ•Tag Eluent A [WAT052890]
The AccQ•Tag Eluent A Concentrate is used for the analysis of protein hydrolysates, foods and feeds, cell cultures, and alkylated cysteines. This concentrated eluate is used as a component of the AccQ•Tag Chemistry Kit.
.jpg)
AccQ•Tag Eluent B [WAT052895]
The AccQ•Tag Eluent B is used for the analysis of protein hydrolysates, foods and feeds, cell cultures, and alkylated cysteine. This ready-to use eluate is used as a component of the AccQ•Tag Chemistry Kit.
.jpg)
AccQ•Tag Ultra Chemistry Kit [176001235]
AccQ•Tag Ultra Refill Package contains the components needed to replenish the chemistries that are a part of the UPLC AAA Application Kit for ACQUITY UPLC and UPLC AAA H-Class Applications Kit. This refill package is not intended to be purchased as part of an initial system.
.jpg)
AccQ•Tag Ultra Derivatization Kit [186003836]
AccQ•Tag Ultra Derivatization Kit is used for derivatizing primary and secondary amino acids in a single step. This kit is a component of the UPLC Amino Acid Analysis (AAA) Application Solution and contains sufficient reagents for 250 analyses.

AccQ•Tag Ultra Eluent A Concentrate [186003838]
The AccQ•Tag™ Ultra Eluent A Concentrate is a concentrated aqueous buffer used as a mobile phase for amino acid analysis of protein hydrolysates, foods and feeds, alkylated cysteines, and cell cultures. This premixed eluate is a component of the AccQ•Tag Ultra Chemistry Kit.
.jpg)
AccQ•Tag Ultra Eluent B [186003839]
The AccQ•Tag Ultra Eluent B is used as a mobile phase for amino acid analysis of protein hydrolysates, foods and feeds, alkylated cysteines, and cell cultures. It is a component of the AccQ•Tag Ultra Chemistry Kit.
.jpg)
AutoPurification System Standard [716000765]
The AutoPurification System Standard allows the user to evaluate and benchmark the performance of an AutoPurification/Preparative System through fraction collection before analysis of critical material. This Quality Control Reference Material is specially formulated to allow the user to verify correct fraction collection. The test is highly valuable when performed at first use/installation, and any time the system has not been used or has had any changes.

Beverage Analysis 5 Standards Solution [186006008]
The Beverage Analysis 5 Standards Solution is intended for the analysis of soft drink formulations for sweeteners and preservatives in conjunction with the Beverage Analysis Standard Solid. This 100 mL solution contains acesulfame-K, saccharin, caffeine, benzoate, and sorbate, and is sold as a refill for use with the Beverage Analysis Kit.

Beverage Analysis Kit [176002534]
The Beverage Analysis kit is a comprehensive, easy-to-use kit for rapid quantitation of 6 commonly used additives (acesulfame-K, saccharin, caffeine, benzoate, sorbate, and aspartame) in soft drink formulations.
.jpg)
Beverage Analysis Mobile Phase Reagent [186006006]
The Beverage Analysis Mobile Phase is used for the analysis of soft drink formulations for sweeteners and preservatives and is a component of the Beverage Analysis Kit. This ready-to-use acetate buffer is available as a refill.

Beverage Analysis Standard Solid [186006010]
The Beverage Analysis Standard Solid is intended for the analysis of soft drink formulations for sweeteners and preservatives in conjunction with the Beverage Analysis 5 Standards Solution. This product is sold as a refill for use with the Beverage Analysis Kit.

Beverage Analysis Wash Reagent [186006007]
The Beverage Analysis Wash Buffer is used for the analysis of soft drink formulations for sweeteners and preservatives and is a component of the Beverage Analysis Kit. One liter of this ready-to-use wash buffer is provided as a refill.

Big-4 Calibration Stock Standard [186007980]
The Big-4 Calibration Stock Standard is a 125 ml solution of four artificial sweeteners and preservatives. The standard is composed of analytes that are traceable via the current lots of the USP reference standards to the SI units and meets ISO Guide 31 on reference materials.
.jpg)
High Level Beverage Analysis Standards [186007232]
The High Level Beverage Analysis Standards mix is used for the analysis of beverages with high caffeine content, such as energy drinks. The product contains caffeine and acesulfame-K standards.
.jpg)
HILIC QC Reference Material [186007226]
The HILIC QC Reference Material is designed for use with UV and MS chromatographic systems using a HILIC column. It is intended to be used as a system benchmarking standard. When used consistently and control charted, the QC Reference Material will provide - confidence in your results - reduce troubleshooting and re-run time - enable cross lab result comparisons It is adaptable to a wide variety of separation methods.

IC Phosphate Calibration Kit [186008046]
The IC Phosphate Calibration Kit (350-550 mg/L) consists of four individual reference standards (three calibration standards at 350, 450, 550 mg/L of phosphate and one check standard at 445 mg/L of phosphate in 18.2 M? deionized water). The standards are intended for use as calibration standards for ion chromatography to analyze phosphate/phosphoric acid levels in beverages.
.jpg)
LC Multiresidue Pesticide Standards Kit [186007574]
The LC Multiresidue Pesticide Standards Kit is a fit-for-purpose collection of 204 compounds designed to eliminate the need for sourcing individual pesticide standards and measure each one manually.

LCMS QC Reference Standard [186006963]
The LCMS QC Reference Standard is designed for use with high performance MS's like Synapt G2-S, Xevo G-S QTof. It is intended to be used as a system benchmarking standard. When used consistently and control charted, the QCRM will provide - confidence in your results - reduce troubleshooting and re-run time - enable cross lab result comparisons The mix is extremely versatile and appropriate for a vast variety of column chemistries and dimensions. It is adaptable to a wide variety of separation methods.

Low Level Beverage Analysis Standards [186007231]
The Low Level Beverage Analysis Standards mix is used for the analysis of beverages with low caffeine content. The product contains caffeine and acesulfame-K standards.
.jpg)
Neutrals QC Reference Material [186006360]
The Neutrals QC Reference Material is designed for use with any chromatographic systems containing a UV detector. It is intended to be used as a system benchmarking standard. The mix contains only neutral compounds. When used consistently and control charted, the QC Reference Material will provide confidence in your results, reduce troubleshooting and re-run time, and enable cross-laboratory result comparisons. This reference material is adaptable to a wide variety of separation methods.

pH 10 Liter [137]
The pH 10 buffer is used to calibrate a pH meter to pH 10 at 25 °C. The buffer is directly traceable to an SI unit via NIST SRMs and contains 1000 mL. This product is accredited to ISO Guide 34.

pH 10 Pint [135]
The pH 10 buffer is used to calibrate a pH meter to pH 10 at 25 °C. The buffer is directly traceable to an SI unit via NIST SRMs and contains (a pint) 473 mL. This product is accredited to ISO Guide 34.

pH 4 Liter [129]
The pH 4 buffer is used to calibrate a pH meter to pH 4 at 25 °C. The buffer is directly traceable to an SI unit via NIST SRMs and contains 1000 mL. This product is accredited to ISO Guide 34.

pH 4 Pint [127]
The pH 4 buffer is used to calibrate a pH meter to pH 4 at 25 °C. The buffer is directly traceable to an SI unit via NIST SRMs and contains (a pint) 473 mL. This product is accredited to ISO Guide 34.

pH 7 Liter [133]
The pH 7 buffer is used to calibrate a pH meter to pH 7 at 25 °C. The buffer is directly traceable to an SI unit via NIST SRMs and contains 1000 mL. This product is accredited to ISO Guide 34.

pH 7 Pint [131]
The pH 7 buffer is used to calibrate a pH meter to pH 7 at 25 °C. The buffer is directly traceable to an SI unit via NIST SRMs and contains (a pint) 473 mL. This product is accredited to ISO Guide 34.

Pico•Tag Chemistry Package for Physiologic Amino Acids [WAT091681]
The Pico•Tag® Chemistry Package for Physiologic Amino Acids is designed for HPLC analysis of physiologic amino acids. The package contains the Pico•Tag column, reagent kit, eluents, diluent, manual, and sample tubes.
.jpg)
Pico•Tag Chemistry Package for Protein Hydrolysates [WAT007360]
Pico•Tag® Chemistry Package is used for the HPLC amino acid analysis of protein hydrolysates, physiologic fluids, feeds, foods, and pharmaceutical preparations. The package contains various reagents, including an HPLC column, reagent kit, eluents, diluent, and manual.
.jpg)
Pico•Tag Diluent [WAT088119]
The Pico•Tag® Diluent is used for reconstituting dried derivatized samples prior to HPLC analysis using the Pico•Tag method.

Pico•Tag Eluent 1 [WAT010960]
The Pico•Tag® Eluent 1 is used for HPLC analysis of physiologic amino acids. This aqueous buffer is packaged as a component of the Pico•Tag Chemistry Kit. Four 1 L bottles of eluent are provided.
.jpg)
Pico•Tag Eluent 2 [WAT010965]
The Pico•Tag® Eluent 2 is used for HPLC analysis of physiologic amino acids. This organic buffer is packaged as a component of the Pico•Tag Chemistry Kit.
.jpg)
Pico•Tag Eluent 2 [WAT010985]
The Pico•Tag® Eluent 2 is used for HPLC analysis of physiologic amino acids. This aqueous buffer is packaged as a component of the Pico•Tag Chemistry Kit. A single 1 L bottle of eluent is provided.
.jpg)
Pico•Tag Eluent A [WAT088108]
The Pico•Tag® Eluent A is an aqueous buffer used as a mobile phase for HPLC separation of amino acids with the Pico•Tag method. Four 1 L bottles are provided.
.jpg)
Pico•Tag Eluent B [WAT010983]
The Pico•Tag® Eluent B is used for HPLC analysis of amino acid in protein hydrolysates. This aqueous buffer is packaged as a component of the Pico•Tag Chemistry Kit. A single 1 L bottle of eluent is provided.
.jpg)
Pico•Tag Eluent B [WAT088112]
The Pico•Tag® Eluent B is an organic buffer used as a mobile phase for HPLC separation of amino acids with the Pico•Tag method. Four 1 L bottles are provided.
.jpg)
Pico•Tag Reagent Kit for Physiologic Amino Acid Analysis [WAT010947]
The Pico•Tag® Reagent Kit for Physiologic Amino Acid Analysis is used for HPLC analysis of physiologic amino acids. This reagent kit contains PITC, TEA and standards (acidic, basic, and neutral standards) and is sold as a refill for use with the Pico•Tag Free Amino Acid Chemistry Package.
.jpg)
Pico•Tag Reagent Kit for Protein Hydrolysates [WAT088123]
The Pico•Tag Reagent Kit for Protein Hydrolysates is used for HPLC analysis of protein hydrolysates. This reagent kit contains PITC, TEA and standards (acidic, basic, and neutral standards) and is sold as a refill for use with the Pico•Tag Chemistry Package for Protein Hydrolysates.
.jpg)
Polybutadiene Standards Kit [WAT035709]
The Polybutadiene Standards Kit is a unique collection of 10 GPC standards (Gel Permeation Chromatography standards) for non-aqueous molecular weight determination. The Polybutadiene Standards Kit covers a molecular weight range from 1000 Daltons to 1,000,000 Daltons
.jpg)
Polyisoprene Standards Kit [WAT035708]
The Polyisoprene Standards Kit is a unique collection of 10 GPC standards (Gel Permeation Chromatography standards) for non-aqueous molecular weight determination. The Polyisoprene Standard Kit covers a molecular weight range from 1000 to 3,000,000 Daltons.
.jpg)
Polymethylmethacrylate Low MW Standards Kit [WAT035707]
The Polymethylmethacrylate Low Molecular Weight Kit is a unique collection of 10 GPC standards (Gel Permeation Chromatography standards) for non-aqueous molecular weight determination. The Polymethylmethacrylate Low Molecular Weight Kit covers a molecular weight range from 1000 to 30,000 Daltons
.jpg)
Polymethylmethacrylate Mid MW Standards Kit [WAT035706]
The Polymethylmethacrylate Mid MW Standard is a unique collection of 10 GPC standards (Gel Permeation Chromatography standards) for non-aqueous molecular weight determination. Polymethylmethacrylate Mid. Molecular Weight Kit covers a molecular weight range from 2400 to 1,000,000 Daltons.
.jpg)
Preparative Chromatography Mix Standard [186006703]
The Preparative Chromatography Mix Standard is a specially formulated mix for the preparative or purification system. The Preparative Chromatography Mix Standard allows the user to evaluate and benchmark their chromatography prep or purification system with UV or MS before analysis of critical material. The Preparative Chromatography Standard includes a void marker, neutral, acidic and basic compounds. It can be used with a variety of column chemistries and dimensions, and system hardware.

Reversed-Phase QC Reference Material [186006363]
The Reversed-Phase QC Reference Material is designed for use with any chromatographic systems containing a UV detector. It is intended to be used as a system benchmarking standard. The Reversed-Phase QC Reference Material is significantly more complex than the Neutrals QC Reference Material in that it contains a void marker, neutral, acidic and basic compounds which could be challenging to separate. It is designed to provide this complexity and is appropriate when complex assays are routinely performed. When used consistently and control charted, the QC Reference Material will provide - confidence in your results - reduce troubleshooting and re-run time - enable cross lab result comparisons It is adaptable to a wide variety of separation methods.

Soft Drink Analysis 4 Component Standard [WAT036889]
The Soft Drink Analysis 4 Component Standard is intended for the analysis of soft drink formulations for sweeteners and preservatives using the NovaPak® C18 Column. The standard mix contains caffeine, benzoate, sorbate, and aspartame standards.
.jpg)
Soft Drink Analysis 5 Component Standard [186003856]
The Soft Drink Analysis 5 Component Standard is used for the analysis of soft drink formulations for sweeteners and preservatives using the SunFire® C18 Column. This standard mix contains caffeine, benzoate, sorbate, acesulfame K, and aspartame.

Soft Drink Mobile Phase for NovaPak Column Analysis [WAT036888]
The Soft Drink Analysis Mobile Phase is intended for the analysis of soft drink formulations for sweeteners and preservatives using the NovaPak® C18 Column. This mobile phase is a pre-mixed solution of denatured ethanol, potassium phosphate, and water.
.jpg)
Soft Drink Mobile Phase for SunFire Column Analysis [186003858]
The Soft Drink Analysis SF36 Mobile Phase is used for the analysis of soft drink formulations for sweeteners and preservatives with the SunFire Column. This is a pre-mixed, ready-to-use solution of denatured ethanol, potassium phosphate, and water.
.jpg)
UPC2 Caffeine Standard [186006614]
The UPC2 Caffeine Standard is intended to assess the reproducibility of the ACQUITY UPC2® System. Separation details can be obtained from the installation method and project.

UPC2 Gradient Standard [186006551]
The UPC2 Gradient Standard is intended to assess reproducibity of the ACQUITY UPC2® System using a gradient separation. Separation details are obtained from the installation method and project.

UPC2 Standard Flavone [186006523]
The UPC2 Standard Flavone is a single component standard which can be used to assess the reproducibility of your Waters ACQUITY UPC2® or SFC system.

UPC2 Standard Flurbiprofen [186006524]
The UPC2 Standard Flurbiprofen is a single component standard which can be used to assess the reproducibility of your Waters ACQUITY UPC2® System or SFC system.

UPC2 Standard Ibuprofen [186006521]
The UPC2 Standard Ibuprofen is a single component standard which can be used to assess the reproducibility of your Waters ACQUITY UPC2® System or SFC system.

UPC2 Standard Mix [186006372]
The UPC2 Standard Mix is intended for use with the Waters ACQUITY UPC system. This four compound mix can be used to assess system performance and reproducibility.

UPC2 Standards Kit [176002811]
The UPC2® Standards Kit combines the UPC2 Gradient Standard Mix and the UPC2 Caffeine Standard products. Use the standard mixtue to assess UPC2 System. Separation details can be obtained from the installation method and project.
.jpg)