The MassPREP™ Protein Digestion Standard Mix 1 is a qualitative standard that provides high confidence and coverage during expression profiling of complex protein samples. This standard is used for verification of Waters PLGS software. It is packaged as a lyophilized powder in a Waters TruView™ Vial (ideal for peptides) and consists of a relatively close equimolar ratio (~1 nmol of each) of yeast enolase (SwissProt P00924), Phosphorylase b (SwissProt P00489), yeast alcohol dehydrogenase (ADH, SwissProt P00330) and bovine serum albumin (BSA, SwissProt P02769), which have all been tryptically digested. Please refer to the COA for the exact ratio since it is lot dependent.

Recommended solubilization for nanoscale (75 um) LC is 1.0 µl / for microscale (300 um) LC in 100 µl of 0.1% formic acid in DI water.

Store at room temperature.

System Performance Standards Key

Set Up

Setup standards are used upon installation of a new system, start-up of a system which has been idle for a period of time, or to re-start a system that has been moved to a new location. These standards may include multiple components within a kit which allow step by step setup and calibration, or they can be single mixtures which will enable a full system assessment and initialization.

Calibration

These standards can be used for instrument calibration. Calibration is usually performed at a frequency that minimizes the risk of being out of calibration, in addition to major events suc h as when the instrument is moved and upon any major repair. Calibration can be confirmed as often as your standard operating procedures recommend. Look for solutions to calibrate your MS mass accuracy and resolution, UV detector linearity, UV and Fluorescence detector wavelength accuracy, injector accuracy and precision, and solvent system flow rate accuracy.

Performance

Your system is comprised of many interdependent components working together. An issue with any one component can produce erroneous final results. All components performing correctly will produce results within an expected variability. Some of the system components include mobile phase, column, tubing, pumping, injecting, temperature controlling, detecting, data collection rate, and integration
parameters. An issue in any one of the components listed can affect your result.
 
Performance Check Standards should be utilized on a routine basis. This includes anytime a column is changed, a method is changed, the instrument is moved, or confirmation of system performance is desired. Confirming the performance of your system can be done on a system basis with suitability standards or per individual instrument component. Benchmark performance should be established after
calibration and confirmed regularly.

Tuning

These Mass Spectrometry solutions are used routinely and are available for every ionization mode. Use the solution to optimize the mass spectrometer setting for optimal signal either manually or through Intellistart.

Hazardous

This product contains hazardous material which requires special freight handling. Additional charges may apply.

Have a Question?

Get Expert Advice!

Contact Us | Sales Offices

Related Product

MassPREP Enolase Digestion Standard [186002325]

The MassPREP™ Enolase Digestion Standard is part of a line of qualitative digestion stan ...

Related Product

MassPREP Phosphorylase b Standard [186002326]

The MassPREP™ Phosphorylase b Digestion Standard is part of a line of qualitative digest ...

Related Product

MassPREP ADH Digestion Standard [186002328]

The MassPREP™ ADH Digestion Standard is part of a line of qualitative digestion standard ...

Related Product

MassPREP BSA Digestion Standard [186002329]

The MassPREP™ BSA Digestion Standard is part of a line of qualitative digestion standard ...

Related Product

MassPREP Digestion Standard Mix 2 [186002866]

The MassPREP™ Protein Digestion Standard Mix 2 is a qualitative standard that provides h ...

34 Maple Street Milford, MA USA
T: 508-478-2000
F: 508-872-1990
Sales Offices

© 2018 Waters Corporation
Terms and Conditions | Privacy Policy