MassPREP Oligonucleotide Standard [186004135]

The MassPREP™ Oligonucleotide Standard is designed for verification of HPLC/UPLC® instruments and performance of columns used for analysis of synthetic oligonucleotides, specifically the ACQUITY® and XBridge® BEH 130 and 300 C18 Columns. This qualitative standard should be used on a regular basis for benchmarking column and system performance.

The standard contains a complex mix of approximately equimolar amounts (~1 nmol) of lyophilized 15, 20, 25, 30 and 35 nucleotide (nt) long oligodeoxythymidines. It is packaged in a Waters TruView™ Vial (ideal for peptides) for direct solubilization and injection. Recommended solubilization is Mobile Phase A, which is 0.1 mM TEAA 0.5 ml.

Store at room temperature.

  • XBridge Oligonucleotide BEH C18 Column, 130Å, 2.5 µm, 2.1 mm X 50 mm, 1/pk (186003852)
  • ACQUITY UPLC Oligonucleotide BEH C18 Column, 130Å, 1.7 µm, 2.1 mm X 150 mm, 1/pk (186005516)
  • Oasis HLB 96-well µElution Plate, 2 mg Sorbent per Well, 30 µm Particle Size, 1/pk (186001828BA)
  • TruView™ LCMS Certified Vials (186005666CV)

System Performance Standards Key

Set Up

Setup standards are used upon installation of a new system, start-up of a system which has been idle for a period of time, or to re-start a system that has been moved to a new location. These standards may include multiple components within a kit which allow step by step setup and calibration, or they can be single mixtures which will enable a full system assessment and initialization.

Calibration

These standards can be used for instrument calibration. Calibration is usually performed at a frequency that minimizes the risk of being out of calibration, in addition to major events suc h as when the instrument is moved and upon any major repair. Calibration can be confirmed as often as your standard operating procedures recommend. Look for solutions to calibrate your MS mass accuracy and resolution, UV detector linearity, UV and Fluorescence detector wavelength accuracy, injector accuracy and precision, and solvent system flow rate accuracy.

Performance

Your system is comprised of many interdependent components working together. An issue with any one component can produce erroneous final results. All components performing correctly will produce results within an expected variability. Some of the system components include mobile phase, column, tubing, pumping, injecting, temperature controlling, detecting, data collection rate, and integration
parameters. An issue in any one of the components listed can affect your result.
 
Performance Check Standards should be utilized on a routine basis. This includes anytime a column is changed, a method is changed, the instrument is moved, or confirmation of system performance is desired. Confirming the performance of your system can be done on a system basis with suitability standards or per individual instrument component. Benchmark performance should be established after
calibration and confirmed regularly.

Tuning

These Mass Spectrometry solutions are used routinely and are available for every ionization mode. Use the solution to optimize the mass spectrometer setting for optimal signal either manually or through Intellistart.

Hazardous

This product contains hazardous material which requires special freight handling. Additional charges may apply.

Have a Question?

Get Expert Advice!

Contact Us | Sales Offices

34 Maple Street Milford, MA USA
T: 508-478-2000
F: 508-872-1990
Sales Offices

© 2018 Waters Corporation
Terms and Conditions | Privacy Policy