ACQUITY UPLC Absorb Start-up Solution [186006683]

The ACQUITY UPLC Absorb Start-up Solution is used to perform system performance tests on the ACQUITY UPLC System with TUV or PDA detectors. This kit can replace part number 700002669 if propiophenone is not required. Tests that can be performed include the system precision and gradient performance tests. Performing these tests verify that the ACQUITY UPLC System is functioning according to its design specifications, producing test results that meet the minimum standards for accuracy and precision. Perform replicate caffeine injections to determine system precision based on retention time and peak area. The 6-component mixture is used to test gradient performance and reproducibility over replicate injections.

The ACQUITY UPLC Absorb Start-up Solution contains:

  • 0.10 mg/mL caffeine in 90/10 water/acetonitrile, 10 mL in an ampule
  • 4.00 μg/mL each: 2-acetylfuran, acetanilide, acetophenone, butylparaben, benzophenone and valerophenone, in 90/10 water/acetonitrile, 10 mL in an ampule.

 

Store at room temperature.

System Performance Standards Key

Set Up

Setup standards are used upon installation of a new system, start-up of a system which has been idle for a period of time, or to re-start a system that has been moved to a new location. These standards may include multiple components within a kit which allow step by step setup and calibration, or they can be single mixtures which will enable a full system assessment and initialization.

Calibration

These standards can be used for instrument calibration. Calibration is usually performed at a frequency that minimizes the risk of being out of calibration, in addition to major events suc h as when the instrument is moved and upon any major repair. Calibration can be confirmed as often as your standard operating procedures recommend. Look for solutions to calibrate your MS mass accuracy and resolution, UV detector linearity, UV and Fluorescence detector wavelength accuracy, injector accuracy and precision, and solvent system flow rate accuracy.

Performance

Your system is comprised of many interdependent components working together. An issue with any one component can produce erroneous final results. All components performing correctly will produce results within an expected variability. Some of the system components include mobile phase, column, tubing, pumping, injecting, temperature controlling, detecting, data collection rate, and integration
parameters. An issue in any one of the components listed can affect your result.
 
Performance Check Standards should be utilized on a routine basis. This includes anytime a column is changed, a method is changed, the instrument is moved, or confirmation of system performance is desired. Confirming the performance of your system can be done on a system basis with suitability standards or per individual instrument component. Benchmark performance should be established after
calibration and confirmed regularly.

Tuning

These Mass Spectrometry solutions are used routinely and are available for every ionization mode. Use the solution to optimize the mass spectrometer setting for optimal signal either manually or through Intellistart.

Hazardous

This product contains hazardous material which requires special freight handling. Additional charges may apply.

Have a Question?

Get Expert Advice!

Contact Us | Sales Offices

Related Product

Neutrals QC Reference Material [186006360]

The Neutrals QC Reference Material is designed for use with any chromatographic systems contai ...

Related Product

ACQUITY UPLC Absorb 10mm Cell Test Solution [186006682]