FI optimization on GCTs only [186006865]

  • Product
  • Documents
  • Columns & Vials

FI optimization on GCTs only [186006865]

The FI optimization on GCTs only standard is intended to optimize the chemical ionization signal and tuning of the GCT/MS system as described in the operator guide. For all MS Users who need to get their system calibrated and working quickly. The FI optimization on GCTs only standard is a ready to use standard calibrator that are easy to use and specially formulate for your MS. Use this standard routinely and realize productivity gains.

The FI optimization on GCTs only standard contains:

  • 700 μL Perfluorotrimethylcyclohexane
  • 200 μL Heptacosa trifluorobutylamine
  • 20 μL Hexafluorobenzene
  • 20 μL Pentafluorobenzene
  • 10 μL Chloropentafluorobenzene
  • 20 μL Xylene
  • 20 μL Acetone in an ampule 

 

Store at room temperature.

System Performance Standards Key

Set Up

Setup standards are used upon installation of a new system, start-up of a system which has been idle for a period of time, or to re-start a system that has been moved to a new location. These standards may include multiple components within a kit which allow step by step setup and calibration, or they can be single mixtures which will enable a full system assessment and initialization.

Calibration

These standards can be used for instrument calibration. Calibration is usually performed at a frequency that minimizes the risk of being out of calibration, in addition to major events suc h as when the instrument is moved and upon any major repair. Calibration can be confirmed as often as your standard operating procedures recommend. Look for solutions to calibrate your MS mass accuracy and resolution, UV detector linearity, UV and Fluorescence detector wavelength accuracy, injector accuracy and precision, and solvent system flow rate accuracy.

Performance

Your system is comprised of many interdependent components working together. An issue with any one component can produce erroneous final results. All components performing correctly will produce results within an expected variability. Some of the system components include mobile phase, column, tubing, pumping, injecting, temperature controlling, detecting, data collection rate, and integration
parameters. An issue in any one of the components listed can affect your result.
 
Performance Check Standards should be utilized on a routine basis. This includes anytime a column is changed, a method is changed, the instrument is moved, or confirmation of system performance is desired. Confirming the performance of your system can be done on a system basis with suitability standards or per individual instrument component. Benchmark performance should be established after
calibration and confirmed regularly.

Tuning

These Mass Spectrometry solutions are used routinely and are available for every ionization mode. Use the solution to optimize the mass spectrometer setting for optimal signal either manually or through Intellistart.

Hazardous

This product contains hazardous material which requires special freight handling. Additional charges may apply.

Have a Question?

Get Expert Advice!

Contact Us | Sales Offices

Related Product

MS Cleaning Solution [186006846]

The MS Cleaning Solution is intended to clean the StepWave ion guide of all MS systems.

Related Product

Resolution Check on all GC-MS products [186006862]

The Resolution Check on all GC-MS products is intended to check the resolution and for routine ...

Related Product

CI optimization on GCTs only [186006863]

The CI optimization on GCTs only is to be used to optimize the chemical ionization signal and ...

Related Product

CI/FI optimization and Tuning on GCTs only [186006864]

The CI/FI optimization and Tuning kit on GCTs only is intended to optimize the chemical ioniza ...

34 Maple Street Milford, MA USA
T: 508-478-2000
F: 508-872-1990
Sales Offices

© 2018 Waters Corporation
Terms and Conditions | Privacy Policy