ACQUITY MS Test Solutions [700002728]

  • Product
  • Documents
  • Columns & Vials
  • Systems

ACQUITY MS Test Solutions [700002728]

The ACQUITY MS Test Solutions is intended for performing operational and performance qualification on an ACQUITY System with a single or triple quadrupole MS instruments, such as the SQD and TQD. This kit is designed for use by a Waters certified engineer or user as part of a performance maintenance or qualification activity. Protocols are available via the purchase of Waters qualification services or self-directed qualification training and license. The MS detector linearity and detector limit can be tested with these standards.

Kit Contents:

  • Two ampules with 1 mg/mL sulfadimethoxine in methanol, 10 mL each (for qualification)
  • One ampule of 1 mg/mL terfenadine in acetonitrile, 10 mL
  • One ampule of 1 mg/mL reserpine in acetonitrile, 10 mL
  • One ampule of 1 mg/mL acetominophen (Paracetamol) in acetonitrile, 10 mL
  • One ampule of caffeine in acetonitrile
  • One bottle of formic acid, 10 mL (provided as a modifier)

 

Dilutions of sulfadimethoxine can be used to perform injector linearity and accuracy, MS detector linearity, system precision, flow rate linearity, and carryover. It can also be used to check reproducibility, sensitivity, peak width, signal to noise, etc. on the MS. The combination of the stock solutions provided can be used to perform gradient testing. Note that since all stock solutions are individually provided in 1 mg/mL concentrations, all compounds listed can be mixed and matched according to one's preference.

Store at room temperature.

System Performance Standards Key

Set Up

Setup standards are used upon installation of a new system, start-up of a system which has been idle for a period of time, or to re-start a system that has been moved to a new location. These standards may include multiple components within a kit which allow step by step setup and calibration, or they can be single mixtures which will enable a full system assessment and initialization.

Calibration

These standards can be used for instrument calibration. Calibration is usually performed at a frequency that minimizes the risk of being out of calibration, in addition to major events suc h as when the instrument is moved and upon any major repair. Calibration can be confirmed as often as your standard operating procedures recommend. Look for solutions to calibrate your MS mass accuracy and resolution, UV detector linearity, UV and Fluorescence detector wavelength accuracy, injector accuracy and precision, and solvent system flow rate accuracy.

Performance

Your system is comprised of many interdependent components working together. An issue with any one component can produce erroneous final results. All components performing correctly will produce results within an expected variability. Some of the system components include mobile phase, column, tubing, pumping, injecting, temperature controlling, detecting, data collection rate, and integration
parameters. An issue in any one of the components listed can affect your result.
 
Performance Check Standards should be utilized on a routine basis. This includes anytime a column is changed, a method is changed, the instrument is moved, or confirmation of system performance is desired. Confirming the performance of your system can be done on a system basis with suitability standards or per individual instrument component. Benchmark performance should be established after
calibration and confirmed regularly.

Tuning

These Mass Spectrometry solutions are used routinely and are available for every ionization mode. Use the solution to optimize the mass spectrometer setting for optimal signal either manually or through Intellistart.

Hazardous

This product contains hazardous material which requires special freight handling. Additional charges may apply.

Have a Question?

Get Expert Advice!

Contact Us | Sales Offices

Related Product

LCMS QC Reference Standard [186006963]

The LCMS QC Reference Standard is designed for use with high performance MS's like Synapt& ...

Related Product

MS Calibration Solution, Atmospheric Pressure Ionization [700001593]

The MS Calibration Solution, Atmospheric Pressure Ionization is used for calibration of mass s ...

Related Product

MS Qualification Standards Kit [700002157]

The MS Qualification Standards Kit is intended to be used in the operational qualification of ...

Related Product

ACQUITY UPLC/UV Qualification Standards Kit [700002642]

The ACQUITY UPLC/UV Qualification Standards Kit is intended for performing system-level perfor ...

34 Maple Street Milford, MA USA
T: 508-478-2000
F: 508-872-1990
Sales Offices

© 2018 Waters Corporation
Terms and Conditions | Privacy Policy