LCT Premier/XE Standards Test Kit [700004027]

  • Product
  • Documents
  • Columns & Vials
  • Systems

LCT Premier/XE Standards Test Kit [700004027]

The LCT Premier/XE Standards Test Kit is intended to be used to qualify and calibrate the LCT Premier/ XE system. This kit is designed for use by a Waters certified engineer or user as part of a performance maintenance or qualification activity.  Protocols in the use of this kit are available via the purchase of Waters qualification services or self directed qualification training and license. The Waters LCT Premier/XE Standard Kit includes 17 standards to be used for the qualification and calibration of the LCT Premier/XE:

  • 0.1 M sodium hydroxide in water, 10 mL in a 15 mL clear bottle
  • 10% Formic Acid in water, 10 mL in a 15 mL brown bottle
  • (2) of 2-propanol/water 90/10,10 mL in a 15 mL clear bottle
  • (5) of 50/50 acetonitrile/water, 20 mL in an ampule
  • Positive Ion Tests: 2 ng/μL leucine enkephalin in 50/50, acetonitrile/water, 10 mL in an ampule 
  • Positive Ion Tests: leucine enkephalin, 2 mg in a 12 mL vial
  • Negative Ion Tests: 5 ng/μL raffinose in 50/50 acetonitrile/water, 10 mL, in an amber ampule
  • Negative Ion Tests: raffinose, 2 mg, in a 12 mL vial
  • Resolution Tests: melittin, 0.3 mg, in a 4 mL vial
  • (2) Resolution Tests: [Glu1]-fibrinopeptide, 0.1 mg, in a 4 mL vial 
  • Positive Ion APcI: 1 ng/μL 17-α-hydroxyprogesterone in 70/30 acetonitrile/water, 10 mL, in an amber ampule
  • Negative Ion APcI: 1 ng/μL sulfadimethoxine in 70/30 acetonitrile/water, 10 mL, in an amber ampule
  • Positive Ion APPI: 1 ng/μL cholesterol in methanol, 10 mL, in an amber ampule • Chromatographic Signal to Noise: reserpine, 2.5 mg, in a 4 mL vial
  • Chromatographic Signal to Noise: ammonium acetate, 5 g, in a nalgene bottle
  • ACQUITY UPLC® + MS Test Mix for Precision: 2 ng/μL sulfadimethoxine in 10/90 acetonitrile/water, 10 mL, in an amber ampule
  • ACQUITY UPLC + MS Test Mix for Gradient Performance: 2 ng/μL each acetominophen, caffeine, sulfadimethoxine, reserpine, terfenadine, in 10/90 acetonitrile/water, 10 mL in an amber ampule
  • Other supplies include: (2) 10 mL Class A volumetric flask & stoppers (2) Pasteur pipettes latex pipette bulb.

 

Store refrigerated 2-5 °C upon arrival for best results

System Performance Standards Key

Set Up

Setup standards are used upon installation of a new system, start-up of a system which has been idle for a period of time, or to re-start a system that has been moved to a new location. These standards may include multiple components within a kit which allow step by step setup and calibration, or they can be single mixtures which will enable a full system assessment and initialization.

Calibration

These standards can be used for instrument calibration. Calibration is usually performed at a frequency that minimizes the risk of being out of calibration, in addition to major events suc h as when the instrument is moved and upon any major repair. Calibration can be confirmed as often as your standard operating procedures recommend. Look for solutions to calibrate your MS mass accuracy and resolution, UV detector linearity, UV and Fluorescence detector wavelength accuracy, injector accuracy and precision, and solvent system flow rate accuracy.

Performance

Your system is comprised of many interdependent components working together. An issue with any one component can produce erroneous final results. All components performing correctly will produce results within an expected variability. Some of the system components include mobile phase, column, tubing, pumping, injecting, temperature controlling, detecting, data collection rate, and integration
parameters. An issue in any one of the components listed can affect your result.
 
Performance Check Standards should be utilized on a routine basis. This includes anytime a column is changed, a method is changed, the instrument is moved, or confirmation of system performance is desired. Confirming the performance of your system can be done on a system basis with suitability standards or per individual instrument component. Benchmark performance should be established after
calibration and confirmed regularly.

Tuning

These Mass Spectrometry solutions are used routinely and are available for every ionization mode. Use the solution to optimize the mass spectrometer setting for optimal signal either manually or through Intellistart.

Hazardous

This product contains hazardous material which requires special freight handling. Additional charges may apply.

Have a Question?

Get Expert Advice!

Contact Us | Sales Offices

Related Product

MS Cleaning Solution [186006846]

The MS Cleaning Solution is intended to clean the StepWave ion guide of all MS systems.

Related Product

MS Leucine Enkephalin Kit [700002456]

The MS Leucine Enkephalin Kit is intended for use when setting up the Time of Flight MS detect ...

Related Product

[Glu1]-Fibrinopeptide B Standard [700004729]

The [Glu1]-Fibrinopeptide B Standard is intended to be used for mass scale calibration and as ...