AutoPurification System Standard [716000765]

  • Product
  • Documents
  • Columns & Vials
  • Systems

AutoPurification System Standard [716000765]

The AutoPurification System Standard allows the user to evaluate and benchmark the performance of an AutoPurification/Preparative System through fraction collection before analysis of critical material. This Quality Control Reference Material is specially formulated to allow the user to verify correct fraction collection. The test is highly valuable when performed on first use/installation, and any time the system has not been used or has had any changes.

The system standard mix contains:

  • 2500 μg/mL thionin
  • 3000 μg/mL thioflavin
  • 2500 μg/mL crystal violet

 

The standard mix is prepared in 25/75 water/methanol. Three 10 mL ampules of the system standard are provided.

 

Store at room temperature.

System Performance Standards Key

Set Up

Setup standards are used upon installation of a new system, start-up of a system which has been idle for a period of time, or to re-start a system that has been moved to a new location. These standards may include multiple components within a kit which allow step by step setup and calibration, or they can be single mixtures which will enable a full system assessment and initialization.

Calibration

These standards can be used for instrument calibration. Calibration is usually performed at a frequency that minimizes the risk of being out of calibration, in addition to major events suc h as when the instrument is moved and upon any major repair. Calibration can be confirmed as often as your standard operating procedures recommend. Look for solutions to calibrate your MS mass accuracy and resolution, UV detector linearity, UV and Fluorescence detector wavelength accuracy, injector accuracy and precision, and solvent system flow rate accuracy.

Performance

Your system is comprised of many interdependent components working together. An issue with any one component can produce erroneous final results. All components performing correctly will produce results within an expected variability. Some of the system components include mobile phase, column, tubing, pumping, injecting, temperature controlling, detecting, data collection rate, and integration
parameters. An issue in any one of the components listed can affect your result.
 
Performance Check Standards should be utilized on a routine basis. This includes anytime a column is changed, a method is changed, the instrument is moved, or confirmation of system performance is desired. Confirming the performance of your system can be done on a system basis with suitability standards or per individual instrument component. Benchmark performance should be established after
calibration and confirmed regularly.

Tuning

These Mass Spectrometry solutions are used routinely and are available for every ionization mode. Use the solution to optimize the mass spectrometer setting for optimal signal either manually or through Intellistart.

Hazardous

This product contains hazardous material which requires special freight handling. Additional charges may apply.

Have a Question?

Get Expert Advice!

Contact Us | Sales Offices

Related Product

Preparative Chromatography Mix Standard [186006703]

The Preparative Chromatography Mix Standard is a specially formulated mix for the preparative ...

Related Product

LCMS QC Reference Standard [186006963]

The LCMS QC Reference Standard is designed for use with high performance MS's like Synapt& ...