UV Wavelength Accuracy Kit (Erbium Perchlorate) [WAT042885]

  • Product
  • Documents
  • Columns & Vials
  • Systems

UV Wavelength Accuracy Kit (Erbium Perchlorate) [WAT042885]

The UV Wavelength Accuracy Kit (Erbium Perchlorate) is used to perform Operational Qualification procedures for wavelength accuracy on HPLC TUV/PDA detectors such as the 2487, 996, 2996, 2489, and 2998 using either cuvettes or via manual delivery with a 10 cc safety syringe. This kit is designed for use by a Waters certified engineer or user as part of a performance maintenance or qualification activity.  Protocols in the use of this kit are available via the purchase of Waters qualification services or self directed qualification training and license.  

The UV Wavelength Accuracy Kit contains and ampule of 10.0 g/L erbium perchlorate in water, 10 mL.

Store at room temperature.

  • XSelect® CSH™ C18 XP Column, 130Å, 2.5 µm, 4.6 mm X 100 mm (186006111)
  • LCMS Certified Vials (600000668CV)
  • TruView™ LCMS Certified Vials (186005666CV)

System Performance Standards Key

Set Up

Setup standards are used upon installation of a new system, start-up of a system which has been idle for a period of time, or to re-start a system that has been moved to a new location. These standards may include multiple components within a kit which allow step by step setup and calibration, or they can be single mixtures which will enable a full system assessment and initialization.

Calibration

These standards can be used for instrument calibration. Calibration is usually performed at a frequency that minimizes the risk of being out of calibration, in addition to major events suc h as when the instrument is moved and upon any major repair. Calibration can be confirmed as often as your standard operating procedures recommend. Look for solutions to calibrate your MS mass accuracy and resolution, UV detector linearity, UV and Fluorescence detector wavelength accuracy, injector accuracy and precision, and solvent system flow rate accuracy.

Performance

Your system is comprised of many interdependent components working together. An issue with any one component can produce erroneous final results. All components performing correctly will produce results within an expected variability. Some of the system components include mobile phase, column, tubing, pumping, injecting, temperature controlling, detecting, data collection rate, and integration
parameters. An issue in any one of the components listed can affect your result.
 
Performance Check Standards should be utilized on a routine basis. This includes anytime a column is changed, a method is changed, the instrument is moved, or confirmation of system performance is desired. Confirming the performance of your system can be done on a system basis with suitability standards or per individual instrument component. Benchmark performance should be established after
calibration and confirmed regularly.

Tuning

These Mass Spectrometry solutions are used routinely and are available for every ionization mode. Use the solution to optimize the mass spectrometer setting for optimal signal either manually or through Intellistart.

Hazardous

This product contains hazardous material which requires special freight handling. Additional charges may apply.

Have a Question?

Get Expert Advice!

Contact Us | Sales Offices

Related Product

UV Wavelength Accuracy Kit (uracil) [WAT042879]

The UV Wavelength Accuracy kit if is used to perform Operational Qualification procedures for ...

Related Product

UV Detector Linearity Standards Kit [WAT042881]

The UV Detector Linearity Standards Kit is designed for linearity testing of UV detectors with ...

Related Product

UV Detector PQ Standard [WAT042887]

The UV Detector PQ Standard Kit contains standards appropriate for assessment of HPLC UV syste ...

34 Maple Street Milford, MA USA
T: 508-478-2000
F: 508-872-1990
Sales Offices

© 2018 Waters Corporation
Terms and Conditions | Privacy Policy