ACQUITY APC Polystyrene Low MW Calibration Kit [186007539]

  • Product
  • Documents
  • Columns & Vials
  • Systems

ACQUITY APC Polystyrene Low MW Calibration Kit [186007539]

APC Calibration Standards were specifically designed to match the molecular weight range of the ACQUITY APC XT Columns.  They eliminate the need to manually prepare custom standard calibration mixes as ACQUITY APC Calibration Standards provide the right number of data points for the targeted MW range. 

Contains:

  • Ten clear vials with green cap; containing 1.5 mg each of polystyrene at Mp 15.7K, 4.92K, 1.25K
  • Ten clear vials with dark blue cap containing 1.5 mg each of polystyrene at Mp 9.13K, 3.47K, 0.474K
  • Ten clear vials with black cap containing 1.5 mg each of polystyrene at Mp 6.54K, 2.28K, 0.266K
  • ACQUITY APC XT - Extended Temperature Column, 200Å, 2.5 µm, 4.6 mm X 150 mm, 1/pk (186007005)
  • ACQUITY APC XT - Extended Temperature Column, 125Å, 2.5 µm, 4.6 mm X 150 mm, 1/pk (186007000)
  • ACQUITY APC XT - Extended Temperature Column, 45Å, 1.7 µm, 4.6 mm X 150 mm, 1/pk (186006995)

System Performance Standards Key

Set Up

Setup standards are used upon installation of a new system, start-up of a system which has been idle for a period of time, or to re-start a system that has been moved to a new location. These standards may include multiple components within a kit which allow step by step setup and calibration, or they can be single mixtures which will enable a full system assessment and initialization.

Calibration

These standards can be used for instrument calibration. Calibration is usually performed at a frequency that minimizes the risk of being out of calibration, in addition to major events suc h as when the instrument is moved and upon any major repair. Calibration can be confirmed as often as your standard operating procedures recommend. Look for solutions to calibrate your MS mass accuracy and resolution, UV detector linearity, UV and Fluorescence detector wavelength accuracy, injector accuracy and precision, and solvent system flow rate accuracy.

Performance

Your system is comprised of many interdependent components working together. An issue with any one component can produce erroneous final results. All components performing correctly will produce results within an expected variability. Some of the system components include mobile phase, column, tubing, pumping, injecting, temperature controlling, detecting, data collection rate, and integration
parameters. An issue in any one of the components listed can affect your result.
 
Performance Check Standards should be utilized on a routine basis. This includes anytime a column is changed, a method is changed, the instrument is moved, or confirmation of system performance is desired. Confirming the performance of your system can be done on a system basis with suitability standards or per individual instrument component. Benchmark performance should be established after
calibration and confirmed regularly.

Tuning

These Mass Spectrometry solutions are used routinely and are available for every ionization mode. Use the solution to optimize the mass spectrometer setting for optimal signal either manually or through Intellistart.

Hazardous

This product contains hazardous material which requires special freight handling. Additional charges may apply.

Have a Question?

Get Expert Advice!

Contact Us | Sales Offices

Related Product

ACQUITY APC Polystyrene Middle MW Calibration Kit [186007540]

APC Calibration Standards were specifically designed to match the molecular weight range of th ...

Related Product

ACQUITY APC Polystyrene High MW Calibration Kit [186007541]

APC Calibration Standards were specifically designed to match the molecular weight range of th ...

Related Product

ACQUITY APC Polystyrene Method Development MW Calibration Kit [186007542]

APC Calibration Standards were specifically designed to match the molecular weight range of th ...

Related Product

ACQUITY APC Polymethylmethacrylate Low MW Calibration Kit [186007543]

APC Calibration Standards were specifically designed to match the molecular weight range of th ...

Related Product

ACQUITY APC Polymethylmethacrylate Middle MW Calibration Kit [186007544]

APC Calibration Standards were specifically designed to match the molecular weight range of th ...

Related Product

ACQUITY APC Polymethylmethacrylate High MW Calibration Kit [186007545]

APC Calibration Standards were specifically designed to match the molecular weight range of th ...

Related Product

ACQUITY APC Polymethylmethacrylate Method Development MW Calibration Kit [186007546]

APC Calibration Standards were specifically designed to match the molecular weight range of th ...

34 Maple Street Milford, MA USA
T: 508-478-2000
F: 508-872-1990
Sales Offices

© 2018 Waters Corporation
Terms and Conditions | Privacy Policy