These multi-component kits and individual standards are used for set-up, tuning, calibration, and sensitivity measurements on a MS single quadrupole detector. These standards are designed to improve for the performance of the following Waters Systems:

  • 3100 Mass Detector
  • SQ Mass Detector
  • SQ Detector 2
  • ZMD Mass Spectrometer
  • ACQUITY® SQD

ACQUITY/Quattro micro or Quattro Premier MS Start Up Solution Kit [700002741]

The ACQUITY/ Quattro Micro or Quattro Premier MS Start Up Solution Kit is intended to perform system precision and system assessment.

Columns & Vials | Systems

LCMS Certified Vials (600000668CV)
TruView LCMS Certified Vials (186005666CV)

ACQUITY QDa Detector

Formic Acid [186006691]

The Formic Acid solution is intended for use with LC or MS systems where formic acid is used as a mobile phase modifier.

MS Cleaning Solution [186006846]

The MS Cleaning Solution is intended to clean the StepWave ion guide of all MS systems.
Xevo® G2-S Tof
Xevo G2-XS Tof

MS Cleaning Solution [186006846]

The MS Cleaning Solution is intended to clean the StepWave ion guide of all MS systems.

LCMS QC Reference Standard [186006963]

The LCMS QC Reference Standard is designed for use with high performance MS's like Synapt G2-S, Xevo G-S QTof. It is intended to be used as a system benchmarking standard. When used consistently and control charted, the QCRM will provide - confidence in your results - reduce troubleshooting and re-run time - enable cross lab result comparisons The mix is extremely versatile and appropriate for a vast variety of column chemistries and dimensions. It is adaptable to a wide variety of separation methods.

Quad LCMS QC Reference Material [186007362]

The Quad LCMS QC Reference Material is designed for use with any chromatographic systems containing a Quad MS such as the SQD, TQD, Xevo TQ. It is intended to be used as a system benchmarking standard. When used consistently and control charted, the QCRM will provide: confidence in your results, reduce troubleshooting and re-run time, and enable cross lab result comparisons. It is adaptable to a wide variety of separation methods. 

[Glu1]-Fibrinopeptide B Standard [700004729]

The [Glu1]-Fibrinopeptide B Standard is intended to be used for mass scale calibration and as a lock mass standard in an easy to use format.

LCMS Certified Vials (600000668CV)
TruView™ LCMS Certified Vials (186005666CV)

VionTM IMS Qtof

MS Cleaning Solution [186006846]

The MS Cleaning Solution is intended to clean the StepWave ion guide of all MS systems.

LCMS QC Reference Standard [186006963]

The LCMS QC Reference Standard is designed for use with high performance MS's like Synapt G2-S, Xevo G-S QTof. It is intended to be used as a system benchmarking standard. When used consistently and control charted, the QCRM will provide - confidence in your results - reduce troubleshooting and re-run time - enable cross lab result comparisons The mix is extremely versatile and appropriate for a vast variety of column chemistries and dimensions. It is adaptable to a wide variety of separation methods.

MS Leucine Enkephalin Kit [700002456]

The MS Leucine Enkephalin Kit is intended for use when setting up the Time of Flight MS detector.

[Glu1]-Fibrinopeptide B Standard [700004729]

The [Glu1]-Fibrinopeptide B Standard is intended to be used for mass scale calibration and as a lock mass standard in an easy to use format.

Leucine Enkephalin [186006013]

MS Calibration Reference Standard - PEG 400 [700004595]

The MS Calibration Reference Standard - PEG 400 is intended to be used for mass calibration. This kit is designed for use by a Waters certified engineer or user as part of a performance maintenance or qualification activity.  Protocols in the use of this kit are available via the purchase of Waters qualification services or self directed qualification training and license.  

Columns & Vials | Systems | Related Products

CI/FI optimization and Tuning on GCTs only [186006864]

The CI/FI optimization and Tuning kit on GCTs only is intended to optimize the chemical ionization signal and tuning of the GCT/MS system as described in the operator guide. For all MS Users who need to get their system calibrated and working quickly. The CI/FI optimization and Tuning kit is a ready to use standard calibrator that are easy to use and specially formulate for your MS. Use this standard routinely and realize productivity gains.

LCMS QC Reference Standard [186006963]

The LCMS QC Reference Standard is designed for use with high performance MS's like Synapt G2-S, Xevo G-S QTof. It is intended to be used as a system benchmarking standard. When used consistently and control charted, the QCRM will provide - confidence in your results - reduce troubleshooting and re-run time - enable cross lab result comparisons The mix is extremely versatile and appropriate for a vast variety of column chemistries and dimensions. It is adaptable to a wide variety of separation methods.

MS Calibration Solution, Atmospheric Pressure Ionization [700001593]

The MS Calibration Solution, Atmospheric Pressure Ionization is used for calibration of mass scale and resolution check of single and triple quads. This kit is designed for use by a Waters certified engineer or user as part of a performance maintenance or qualification activity.  Protocols in the use of this kit are available via the purchase of Waters qualification services or self directed qualification training and license.  

MS Set Up Solution, Atmospheric Pressure Ionization [700001594]

The MS Set Up Solution, Atmospheric Pressure Ionization is intended to be used for Mass Spec Set up. This kit is designed for use by a Waters certified engineer or user as part of a performance maintenance or qualification activity.  Protocols in the use of this kit are available via the purchase of Waters qualification services or self directed qualification training and license.   Note that many of the compounds are concentrated and should be diluted for use with the Xevo®series, or even the SQD.

MS Calibration Solution, Atmospheric Pressure Ionization [700001593]

The MS Calibration Solution, Atmospheric Pressure Ionization is used for calibration of mass scale and resolution check of single and triple quads. This kit is designed for use by a Waters certified engineer or user as part of a performance maintenance or qualification activity.  Protocols in the use of this kit are available via the purchase of Waters qualification services or self directed qualification training and license.  

Columns & Vials | Systems | Related Products

CI/FI optimization and Tuning on GCTs only [186006864]

The CI/FI optimization and Tuning kit on GCTs only is intended to optimize the chemical ionization signal and tuning of the GCT/MS system as described in the operator guide. For all MS Users who need to get their system calibrated and working quickly. The CI/FI optimization and Tuning kit is a ready to use standard calibrator that are easy to use and specially formulate for your MS. Use this standard routinely and realize productivity gains.

LCMS QC Reference Standard [186006963]

The LCMS QC Reference Standard is designed for use with high performance MS's like Synapt G2-S, Xevo G-S QTof. It is intended to be used as a system benchmarking standard. When used consistently and control charted, the QCRM will provide - confidence in your results - reduce troubleshooting and re-run time - enable cross lab result comparisons The mix is extremely versatile and appropriate for a vast variety of column chemistries and dimensions. It is adaptable to a wide variety of separation methods.

MS Set Up Solution, Atmospheric Pressure Ionization [700001594]

The MS Set Up Solution, Atmospheric Pressure Ionization is intended to be used for Mass Spec Set up. This kit is designed for use by a Waters certified engineer or user as part of a performance maintenance or qualification activity.  Protocols in the use of this kit are available via the purchase of Waters qualification services or self directed qualification training and license.   Note that many of the compounds are concentrated and should be diluted for use with the Xevo®series, or even the SQD.

Xevo TQ-S Qualification Standards KIT [700005472]

The Xevo TQ-S Qualification Standards Kit is intended to qualify the Xevo TQ-S System. This kit is designed for use by a Waters certified engineer or user as part of a performance maintenance or qualification activity.  Protocols in the use of this kit are available via the purchase of Waters qualification services or self directed qualification training and license.  

MS Solution - Daidzein (250 µg/L) [700002339]

The MS Solution - Daidzein (250 μg/L) is used to assess signal to noise on triple quad systems. This kit is designed for use by a Waters certified engineer or user as part of a performance maintenance or qualification activity.  Protocols in the use of this kit are available via the purchase of Waters qualification services or self directed qualification training and license.  

Columns & Vials | Systems | Related Products

CI/FI optimization and Tuning on GCTs only [186006864]

The CI/FI optimization and Tuning kit on GCTs only is intended to optimize the chemical ionization signal and tuning of the GCT/MS system as described in the operator guide. For all MS Users who need to get their system calibrated and working quickly. The CI/FI optimization and Tuning kit is a ready to use standard calibrator that are easy to use and specially formulate for your MS. Use this standard routinely and realize productivity gains.

LCMS QC Reference Standard [186006963]

The LCMS QC Reference Standard is designed for use with high performance MS's like Synapt G2-S, Xevo G-S QTof. It is intended to be used as a system benchmarking standard. When used consistently and control charted, the QCRM will provide - confidence in your results - reduce troubleshooting and re-run time - enable cross lab result comparisons The mix is extremely versatile and appropriate for a vast variety of column chemistries and dimensions. It is adaptable to a wide variety of separation methods.

Performance and Operation Solutions for MS [700001332]

The Performance and Operation Solutions for MS is intended to be used to assess the performance and operation of single and triple quad systems. This kit is designed for use by a Waters certified engineer or user as part of a performance maintenance or qualification activity.  Protocols in the use of this kit are available via the purchase of Waters qualification services or self directed qualification training and license.  

MS Qualification Standards Kit [700002157]

The MS Qualification Standards Kit is intended to be used in the operational qualification of several MS's such as the Q-Micro and ZQ. This kit is designed for use by a Waters certified engineer or user as part of a performance maintenance or qualification activity.  Protocols in the use of this kit are available via the purchase of Waters qualification services or self directed qualification training and license.  

Reserpine Kit [700001673]

The Reserpine Kit is a daily use stock solution standard that should be used to optimize tune parameters and signal of your Triple Quad or Single Quad MS. The working solution can be used daily to perform ESI positive sensitivity testing.

Columns & Vials | Systems | Related Products

CI/FI optimization and Tuning on GCTs only [186006864]

The CI/FI optimization and Tuning kit on GCTs only is intended to optimize the chemical ionization signal and tuning of the GCT/MS system as described in the operator guide. For all MS Users who need to get their system calibrated and working quickly. The CI/FI optimization and Tuning kit is a ready to use standard calibrator that are easy to use and specially formulate for your MS. Use this standard routinely and realize productivity gains.

LCMS QC Reference Standard [186006963]

The LCMS QC Reference Standard is designed for use with high performance MS's like Synapt G2-S, Xevo G-S QTof. It is intended to be used as a system benchmarking standard. When used consistently and control charted, the QCRM will provide - confidence in your results - reduce troubleshooting and re-run time - enable cross lab result comparisons The mix is extremely versatile and appropriate for a vast variety of column chemistries and dimensions. It is adaptable to a wide variety of separation methods.

MS Calibration Solution, Atmospheric Pressure Ionization [700001593]

The MS Calibration Solution, Atmospheric Pressure Ionization is used for calibration of mass scale and resolution check of single and triple quads. This kit is designed for use by a Waters certified engineer or user as part of a performance maintenance or qualification activity.  Protocols in the use of this kit are available via the purchase of Waters qualification services or self directed qualification training and license.  

Xevo TQ-S Qualification Standards KIT [700005472]

The Xevo TQ-S Qualification Standards Kit is intended to qualify the Xevo TQ-S System. This kit is designed for use by a Waters certified engineer or user as part of a performance maintenance or qualification activity.  Protocols in the use of this kit are available via the purchase of Waters qualification services or self directed qualification training and license.  

SQD Set Up Solution [700003105]

The SQD Set Up Solution is used as the set up solutions for single and triple quads. This kit is designed for use by a Waters certified engineer or user as part of a performance maintenance or qualification activity.  Protocols in the use of this kit are available via the purchase of Waters qualification services or self directed qualification training and license.  

Columns & Vials | Systems | Related Products

Tuning Solution/Gradient Performance, Sensitivity and Precision [186006861]

The Tuning Solution/Gradient Performance, Sensitivity and Precision is intended to be used to perform tuning, gradient performance sensititivty and precision testing. The mix can be used on a daily basis. It comes in a 25 mL screw-on infusion container.

CI/FI optimization and Tuning on GCTs only [186006864]

The CI/FI optimization and Tuning kit on GCTs only is intended to optimize the chemical ionization signal and tuning of the GCT/MS system as described in the operator guide. For all MS Users who need to get their system calibrated and working quickly. The CI/FI optimization and Tuning kit is a ready to use standard calibrator that are easy to use and specially formulate for your MS. Use this standard routinely and realize productivity gains.

LCMS QC Reference Standard [186006963]

The LCMS QC Reference Standard is designed for use with high performance MS's like Synapt G2-S, Xevo G-S QTof. It is intended to be used as a system benchmarking standard. When used consistently and control charted, the QCRM will provide - confidence in your results - reduce troubleshooting and re-run time - enable cross lab result comparisons The mix is extremely versatile and appropriate for a vast variety of column chemistries and dimensions. It is adaptable to a wide variety of separation methods.

SQD Standards Kit [700003093]

The SQD Standards Kit for SQD system assessment. This kit is designed for use by a Waters certified engineer or user as part of a performance maintenance or qualification activity.  Protocols in the use of this kit are available via the purchase of Waters qualification services or self directed qualification training and license.  

Tuning Solution/Gradient Performance, Sensitivity and Precision [186006861]

The Tuning Solution/Gradient Performance, Sensitivity and Precision is intended to be used to perform tuning, gradient performance sensititivty and precision testing. The mix can be used on a daily basis. It comes in a 25 mL screw-on infusion container.

Columns & Vials | Systems | Related Products

CI/FI optimization and Tuning on GCTs only [186006864]

The CI/FI optimization and Tuning kit on GCTs only is intended to optimize the chemical ionization signal and tuning of the GCT/MS system as described in the operator guide. For all MS Users who need to get their system calibrated and working quickly. The CI/FI optimization and Tuning kit is a ready to use standard calibrator that are easy to use and specially formulate for your MS. Use this standard routinely and realize productivity gains.

MS Calibration Solution, Atmospheric Pressure Ionization [700001593]

The MS Calibration Solution, Atmospheric Pressure Ionization is used for calibration of mass scale and resolution check of single and triple quads. This kit is designed for use by a Waters certified engineer or user as part of a performance maintenance or qualification activity.  Protocols in the use of this kit are available via the purchase of Waters qualification services or self directed qualification training and license.  

SQD Set Up Solution [700003105]

The SQD Set Up Solution is used as the set up solutions for single and triple quads. This kit is designed for use by a Waters certified engineer or user as part of a performance maintenance or qualification activity.  Protocols in the use of this kit are available via the purchase of Waters qualification services or self directed qualification training and license.  

Reserpine Kit [700001673]

The Reserpine Kit is a daily use stock solution standard that should be used to optimize tune parameters and signal of your Triple Quad or Single Quad MS. The working solution can be used daily to perform ESI positive sensitivity testing.