- Advanced Polymer Chromatography (APC)
- UPLC with UV Detection
- GC
- GC-MS
- HPLC with RI, ELSD, Electrochemical, Fluorescence or Conductivity Detection
- HPLC or Prep Systems with UV Detection
- SFC and Convergence Chromatography (UPC2)
- Single Quadrupole Mass Detection
- Tandem Quadrupole (Triple Quadrupole )
- Time-of-flight Mass Spectrometry
- Amino Acids
- Cations
- Gel Filtration
- Gel Permeation
- Glycans
- Ion Calibration
- Oligonucleotides
- Peptides
- Pesticides
- Proteins
- QC Trace Metals
- Small Molecules
- Total Chlorine
- pH Buffers
- Quality Control (QC) Reference Material
- Reagents
- System Performance Standards and Reagents
Find Your Results


These multi-component and individual compound kits are commonly used to perform a series of system-level performance tests for MS time-of-flight installation and as routine use standards and calibrants. ESI positive and negative sensitivity and precision, APCI sensitivity and precision can be assessed. Many protein and digestion calibration standards are also available. These standards are designed to improve for the performance of the following Waters Systems:
- Xevo® QTof
- Xevo G2-S QTof
- SYNAPT® MS/HDMS/MALDI
- SYNAPT G2-S/SI MS/HDMS
- SYNAPT G2 MS HDMS/MALDI
- SYNAPT G2 MS/HDMS
- Q-Tof Premier™/MALDI
- Q-Tof Premier
- QTof/QTof2/QTof APIUS/QTofUltima Family/QTof micro
- MALDI micro MS
- Xevo G2 Tof
- Xevo GS-S Tof
[Glu1]-Fibrinopeptide B Standard [700004729]
The [Glu1]-Fibrinopeptide B Standard is intended to be used for mass scale calibration and as a lock mass standard in an easy to use format.

GlycoWorks HILIC 1 cc Flangeless Catridge [186007239]
The GlycoWorks HILIC 1 cc Flangeless Cartridge Pack is dual purpose; the cartidges can be used for both the extraction of glycans as well as the removal of excess labeling reagent. The flangeless version is designed specifically for customers who use the positive pressure manifold (PPM).

HDMS Standard Kit/Reversed Peptide Kit [700005089]
The HDMS Standard Kit/Reversed Peptide Kit contains three well characterized samples intended to calibrate ion mobility spectrometry/mass spectrometry (IMS/MS) systems.

LCT Premier/XE Standards Test Kit [700004027]
The LCT Premier/XE Standards Test Kit is intended to be used to qualify and calibrate the LCT Premier/ XE system. This kit is designed for use by a Waters certified engineer or user as part of a performance maintenance or qualification activity. Protocols in the use of this kit are available via the purchase of Waters qualification services or self directed qualification training and license.
.jpg)
Mass Scale and Resolution Set Up Solution [700003917]
The Mass Scale and Resolution Set Up Solution is intended to be used to calibrate the mass scale and resultion of your MS. This kit is designed for use by a Waters certified engineer or user as part of a performance maintenance or qualification activity. Protocols in the use of this kit are available via the purchase of Waters qualification services or self directed qualification training and license.

MassPREP ADH Digestion Standard [186002328]
The MassPREP™ ADH Digestion Standard is part of a line of qualitative digestion standards used for performance evaluation of HPLC, UPLC® Columns and LC-MS instrumentation. It is especially useful in positive ion mode evaluations for sensitivity, resolution, and mass measurement accuracy on nanoAcquity and QToF™ based systems. Each digestion standard is batch manufactured with high-grade quality digestion materials and enzymes and is subsequently purified and quality control tested to ensure intra-lot reproducibility.

MassPREP Enolase Digestion Standard [186002325]
The MassPREP™ Enolase Digestion Standard is part of a line of qualitative digestion standards used for performance evaluation of HPLC, UPLC® Columns and LC-MS instrumentation. It is especially useful in positive ion mode evaluations for sensitivity, resolution, and mass measurement accuracy on nanoAcquity and QToF™ based systems. Each digestion standard is batch manufactured with high-grade quality digestion materials and enzymes and is subsequently purified and quality control tested to ensure intra-lot reproducibility.

MS ETD Reagent Kit [700005669]
The MS ETD Reagent Kit is The MS ETD Standards Kit is used to assess electron transfer dissociation on the Synapt® G2 and G2-S. This kit is designed for use by a Waters certified engineer or user as part of a performance maintenance or qualification activity. Protocols in the use of this kit are available via the purchase of Waters qualification services or self directed qualification training and license.

MS ETD Standards Kit [700005666]
The MS ETD Standards Kit is used to assess electron transfer dissociation on the Synapt® G2 and G2-S. This kit is designed for use by a Waters certified engineer or user as part of a performance maintenance or qualification activity. Protocols in the use of this kit are available via the purchase of Waters qualification services or self directed qualification training and license.

MS Leucine Enkephalin Kit [700002456]
The MS Leucine Enkephalin Kit is intended for use when setting up the Time of Flight MS detector.

MS Reference Standard/ Horse Heart Myoglobin [700004749]
The MS Reference Standard/ Horse Heart Myoglobin standard is used for positive ion calibration on a QToF system.

Q-Tof Qualification Standards Kit [700003276]
The Q-Tof™ Qualification Standards Kit is intended to assess the performance of the QTof system. This kit is designed for use by a Waters certified engineer or user as part of a performance maintenance or qualification activity. Protocols in the use of this kit are available via the purchase of Waters qualification services or self directed qualification training and license.

Q-Tof Standards Kit without Bovine [700004768]
The Q-Tof™ Standards Kit without Bovine is intended to be used to qualify the QToF System. This kit is designed for use by a Waters certified engineer or user as part of a performance maintenance or qualification activity. Protocols in the use of this kit are available via the purchase of Waters qualification services or self directed qualification training and license.

ToF G2-S Sample Kit -1 [700008842]
The ToF G2-S Sample Kit -1 is intended for the verification of system performance for Tof G2-S. This kit is designed for use by a Waters certified engineer or user as part of a performance maintenance or qualification activity. Protocols in the use of this kit are available via the purchase of Waters qualification services or self directed qualification training and license.

Vion Test Mix [186008462]
The Vion Test Mix is a 9 component mixture used as a comprehensive reference standard for the Vion IMS QTof system.