The following standards and standards kits are used for the calibration and assessment of ACQUITY UPLC® and HPLC system performance. Use of these standards and kits to benchmark and continuously monitor typical baseline performance will enhance productivity and increase the accuracy of results. These standards are designed to improve for the performance of the following Waters Systems:

  • ACQUITY UPLC
  • ACQUITY UPLC I-Class
  • ACQUITY UPLC H-Class
  • nanoACQUITY®
  • ACQUITY® PDA
  • ACQUITY 2296
  • ACQUITY Enhanced TUV
  • ACQUITY TUV

ACQUITY UPLC Abs 25 mm Cell Test Solutions [186006694]

The ACQUITY UPLC Absorbance 25 mm Cell Test Solution is used to assess the performance of an ACQUITY UPLC System with 25 mm UV flow cell. This kit is designed for use by a Waters certified engineer or user as part of a performance maintenance or qualification activity.  Protocols are available via the purchase of Waters qualification services or self-directed qualification training and license.  This kit can replace part number 700002669 if propiophenone is not required.

Systems | Related Products

Neutrals QC Reference Material [186006360]

The Neutrals QC Reference Material is designed for use with any chromatographic systems containing a UV detector. It is intended to be used as a system benchmarking standard. The mix contains only neutral compounds. When used consistently and control charted, the QC Reference Material will provide confidence in your results, reduce troubleshooting and re-run time, and enable cross-laboratory result comparisons. This reference material is adaptable to a wide variety of separation methods. 

ACQUITY UPLC Absorb 10mm Cell Test Solution [186006682]

The ACQUITY UPLC® Absorb 10mm Cell Test Solution is used to perform system-level performance qualification on an ACQUITY System with TUV or PDA detectors, with or without an ELS detector in line, using the standard 10 mm flow cell configuration. This kit is designed for use by a Waters certified engineer or user as part of a performance maintenance or qualification activity.  Protocols are available via the purchase of Waters qualification services or self-directed qualification training and license.  

Please contact your local office for more information on certification and training service. 

The product can replace part number 700002642 if propiophenone is not required.

ACQUITY UPLC Absorb Start-up Solution [186006683]

The ACQUITY UPLC Absorb Start-up Solution is used to perform system performance tests on the ACQUITY UPLC System with TUV or PDA detectors. This kit is designed for use by a Waters certified engineer or user as part of a performance maintenance or qualification activity.  Protocols in the use of this kit are available via the purchase of Waters qualification services or self directed qualification training and license. This kit can replace part number 700002669 if propiophenone is not required.

ACQUITY UPLC/UV and ELSD Qualification Standards Kit [700002848]

The ACQUITY UPLC/UV and ELSD Qualification Standards Kit is intended for performing the system precision performance test on the ACQUITY UPLC System with an ELSD (evaporative light scattering detector). This kit is designed for use by a Waters certified engineer or user as part of a performance maintenance or qualification activity.  Protocols are available via the purchase of Waters qualification services or self-directed qualification training and license.  

Columns & Vials | Systems | Related Products
  • ACQUITY UPLC BEH C18 Method Validation Kit, 130Å, 1.7 µm, 2.1 mm X 50 mm, 3/pkg (186004044)
  • LCMS Certified Vials (600000668CV)
  • TruView LCMS Certified Vials (186005666CV)

ACQUITY UPLC/UV Qualification Standards Kit [700002642]

The ACQUITY UPLC/UV Qualification Standards Kit is intended for performing system-level performance qualification on an ACQUITY System with TUV or PDA detectors, with or without an ELS detector in line, using the standard 10-mm flow cell configuration. This kit is designed for use by a Waters certified engineer or user as part of a performance maintenance or qualification activity.  Protocols are available via the purchase of Waters qualification services or self directed qualification training and license.  

ACQUITY UPLC/UV Qualification Standards Kit [700002642]

The ACQUITY UPLC/UV Qualification Standards Kit is intended for performing system-level performance qualification on an ACQUITY System with TUV or PDA detectors, with or without an ELS detector in line, using the standard 10-mm flow cell configuration. This kit is designed for use by a Waters certified engineer or user as part of a performance maintenance or qualification activity.  Protocols are available via the purchase of Waters qualification services or self directed qualification training and license.  

Columns & Vials | Systems | Related Products
  • ACQUITY UPLC BEH C18 Method Validation Kit, 130Å, 1.7 µm, 2.1 mm X 50 mm, 3/pkg (186004044)

ACQUITY UPLC/UV Start Up Standards Kit [700002669]

The ACQUITY UPLC/UV Start Up Standards Kit is intended to perform system precision and gradient performance tests on an ACQUITY UPLC System with a UV detector.

ACQUITY UPLC/UV Qualification Standards Kit 25 mm Flow Cell [700002846]

The ACQUITY UPLC/UV Qualification Standards Kit 25 mm Flow Cell is intended to perform system precision, detector wavelength accuracy, detector linearity and sensitivity, gradient performance, carryover, injector linearity and accuracy, flow rate linearity, sample positioning, detector noise, and ELS response. This kit is designed for use by a Waters certified engineer or user as part of a performance maintenance or qualification activity.  Protocols are available via the purchase of Waters qualification services or self-directed qualification training and license.  

Columns & Vials | Systems | Related Products
  • ACQUITY UPLC BEH C18 Method Validation Kit, 130Å, 1.7 µm, 2.1 mm X 50 mm, 3/pkg (186004044)
  • LCMS Certified Vials (600000668CV)
  • TruView™ LCMS Certified Vials (186005666CV)

Neutrals QC Reference Material [186006360]

The Neutrals QC Reference Material is designed for use with any chromatographic systems containing a UV detector. It is intended to be used as a system benchmarking standard. The mix contains only neutral compounds. When used consistently and control charted, the QC Reference Material will provide confidence in your results, reduce troubleshooting and re-run time, and enable cross-laboratory result comparisons. This reference material is adaptable to a wide variety of separation methods. 

ACQUITY UPLC/UV Qualification Standards Kit for 3 mm or 5 mm Flow Cell [700004380]

The ACQUITY UPLC/UV Qualification Standards Kit for 3 mm or 5 mm Flow Cell is intended to be used with a 3 mm or 5 mm TUV or PDA flow cell for calibration and qualification of an ACQUITY/UV system. This kit is designed for use by a Waters certified engineer or user as part of a performance maintenance or qualification activity.  Protocols are available via the purchase of Waters qualification services or self-directed qualification training and license.  

Columns & Vials | Systems
  • ACQUITY UPLC BEH C18 Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 3/pkg (176000863)
  • ACQUITY UPLC BEH C18 Method Validation Kit, 130Å, 1.7 µm, 2.1 mm X 50 mm, 3/pkg (186004044)
  • TruView LCMS Certified Vials (186005666CV)

ACQUITY UPLC/UV Start Up Standards Kit [700002669]

The ACQUITY UPLC/UV Start Up Standards Kit is intended to perform system precision and gradient performance tests on an ACQUITY UPLC System with a UV detector.

Columns & Vials | Systems | Related Products
  • ACQUITY UPLC BEH C18 Method Validation Kit, 130Å, 1.7 µm, 2.1 mm X 50 mm, 3/pkg (186004044)
  • LCMS Certified Vials (600000668CV)
  • TruView LCMS Certified Vials (186005666CV)

ACQUITY UPLC/UV Qualification Standards Kit [700002642]

The ACQUITY UPLC/UV Qualification Standards Kit is intended for performing system-level performance qualification on an ACQUITY System with TUV or PDA detectors, with or without an ELS detector in line, using the standard 10-mm flow cell configuration. This kit is designed for use by a Waters certified engineer or user as part of a performance maintenance or qualification activity.  Protocols are available via the purchase of Waters qualification services or self directed qualification training and license.  

TQD/Q-Premier/XE/Q-Micro Qualification Standards Test Kit [700002646]

The TQD/Q-Premier/XE/Q-Micro Qualification Standards Test Kit is intended to be used to perform system-level performance qualification on a TQD, Q-Premier, XE or Q-Micro. This kit is designed for use by a Waters certified engineer or user as part of a performance maintenance or qualification activity.  Protocols in the use of this kit are available via the purchase of Waters qualification services or self directed qualification training and license.  

AquaAnalysis System Start up Solution [700003870]

The AquaAnalysis System Start up Solution intended to be used during installation and to assess the performance of the AquaAnalysis System. This kit is designed for use by a Waters certified engineer or user as part of a performance maintenance or qualification activity.  Protocols in the use of this kit are available via the purchase of Waters qualification services or self directed qualification training and license.  

Columns & Vials | Systems

AutoPurification System Standard [716000765]

The AutoPurification System Standard allows the user to evaluate and benchmark the performance of an AutoPurification/Preparative System through fraction collection before analysis of critical material. This Quality Control Reference Material is specially formulated to allow the user to verify correct fraction collection. The test is highly valuable when performed at first use/installation, and any time the system has not been used or has had any changes.

Columns & Vials | Systems | Related Products

Preparative Chromatography Mix Standard [186006703]

The Preparative Chromatography Mix Standard is a specially formulated mix for the preparative or purification system. The Preparative Chromatography Mix Standard allows the user to evaluate and benchmark their chromatography prep or purification system with UV or MS before analysis of critical material. The Preparative Chromatography Standard includes a void marker, neutral, acidic and basic compounds. It can be used with a variety of column chemistries and dimensions, and system hardware.

LCMS QC Reference Standard [186006963]

The LCMS QC Reference Standard is designed for use with high performance MS's like Synapt G2-S, Xevo G-S QTof. It is intended to be used as a system benchmarking standard. When used consistently and control charted, the QCRM will provide - confidence in your results - reduce troubleshooting and re-run time - enable cross lab result comparisons The mix is extremely versatile and appropriate for a vast variety of column chemistries and dimensions. It is adaptable to a wide variety of separation methods.

Neutrals QC Reference Material [186006360]

The Neutrals QC Reference Material is designed for use with any chromatographic systems containing a UV detector. It is intended to be used as a system benchmarking standard. The mix contains only neutral compounds. When used consistently and control charted, the QC Reference Material will provide confidence in your results, reduce troubleshooting and re-run time, and enable cross-laboratory result comparisons. This reference material is adaptable to a wide variety of separation methods. 

Columns & Vials | Systems | Related Products

Reversed-Phase QC Reference Material [186006363]

The Reversed-Phase QC Reference Material is designed for use with any chromatographic systems containing a UV detector. It is intended to be used as a system benchmarking standard. The Reversed-Phase QC Reference Material is significantly more complex than the Neutrals QC Reference Material in that it contains a void marker, neutral, acidic and basic compounds which could be challenging to separate. It is designed to provide this complexity and is appropriate when complex assays are routinely performed. When used consistently and control charted, the QC Reference Material will provide - confidence in your results - reduce troubleshooting and re-run time - enable cross lab result comparisons It is adaptable to a wide variety of separation methods.

LCMS QC Reference Standard [186006963]

The LCMS QC Reference Standard is designed for use with high performance MS's like Synapt G2-S, Xevo G-S QTof. It is intended to be used as a system benchmarking standard. When used consistently and control charted, the QCRM will provide - confidence in your results - reduce troubleshooting and re-run time - enable cross lab result comparisons The mix is extremely versatile and appropriate for a vast variety of column chemistries and dimensions. It is adaptable to a wide variety of separation methods.

Preparative Chromatography Mix Standard [186006703]

The Preparative Chromatography Mix Standard is a specially formulated mix for the preparative or purification system. The Preparative Chromatography Mix Standard allows the user to evaluate and benchmark their chromatography prep or purification system with UV or MS before analysis of critical material. The Preparative Chromatography Standard includes a void marker, neutral, acidic and basic compounds. It can be used with a variety of column chemistries and dimensions, and system hardware.

Columns & Vials | Systems | Related Products
  • XBridge® BEH C18 OBD Prep Column, 130Å, 5 µm, 19 mm X 50 mm (186002977)
  • XTerra® MS C18 OBD Prep Column, 125Å, 5 µm, 19 mm X 50 mm (186001930)
  • LCMS Certified Vials (600000668CV)
  • TruView™ LCMS Certified Vials (186005666CV)

AutoPurification System Standard [716000765]

The AutoPurification System Standard allows the user to evaluate and benchmark the performance of an AutoPurification/Preparative System through fraction collection before analysis of critical material. This Quality Control Reference Material is specially formulated to allow the user to verify correct fraction collection. The test is highly valuable when performed at first use/installation, and any time the system has not been used or has had any changes.

Reversed-Phase QC Reference Material [186006363]

The Reversed-Phase QC Reference Material is designed for use with any chromatographic systems containing a UV detector. It is intended to be used as a system benchmarking standard. The Reversed-Phase QC Reference Material is significantly more complex than the Neutrals QC Reference Material in that it contains a void marker, neutral, acidic and basic compounds which could be challenging to separate. It is designed to provide this complexity and is appropriate when complex assays are routinely performed. When used consistently and control charted, the QC Reference Material will provide - confidence in your results - reduce troubleshooting and re-run time - enable cross lab result comparisons It is adaptable to a wide variety of separation methods.

Columns & Vials | Systems | Related Products
  • CORTECS C18 Column, 90Å, 2.7 µm, 2.1 mm X 50 mm, 1/pk (186007365)
  • ACQUITY UPLC BEH C18 Column, 130Å, 1.7 µm, 2.1 mm X 50 mm, 1/pk (186002350)
  • LCMS Certified Vials (600000668CV)
  • TruView LCMS Certified Vials (186005666CV)

System Evaluation Matrix #1 [186006962]

The System Evaluation Matrix #1 is intended for use as a reproducible background signal in the evaluation of LC and MS system performance. It is especially suitable for standard small molecule applications where a complicated matrix is required but naturally occurring alternatives, such as urine and plasma, are impractical.

Neutrals QC Reference Material [186006360]

The Neutrals QC Reference Material is designed for use with any chromatographic systems containing a UV detector. It is intended to be used as a system benchmarking standard. The mix contains only neutral compounds. When used consistently and control charted, the QC Reference Material will provide confidence in your results, reduce troubleshooting and re-run time, and enable cross-laboratory result comparisons. This reference material is adaptable to a wide variety of separation methods. 

LCMS QC Reference Standard [186006963]

The LCMS QC Reference Standard is designed for use with high performance MS's like Synapt G2-S, Xevo G-S QTof. It is intended to be used as a system benchmarking standard. When used consistently and control charted, the QCRM will provide - confidence in your results - reduce troubleshooting and re-run time - enable cross lab result comparisons The mix is extremely versatile and appropriate for a vast variety of column chemistries and dimensions. It is adaptable to a wide variety of separation methods.

QDa QC Reference Material [186007345]

The QDa QC Reference Material is designed for use with Waters ACQUITY QDa Detector.  It is intended to be used as a system benchmarking standard.  
 
The mix is extremely versatile and appropriate for a vast majority of column chemistries and dimensions. It is adaptable to a wide variety of separation methods.